Skip to main content
Log in

Indirect complexometric determination of cadmium(II) using 1,10-phenanthroline as selective masking agent

  • Original Papers
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract

An indirect complexometric method is described for the determination of cadmium(II), 1,10-phenanthroline being used as masking agent. Cadmium(II) in a given sample solution is initially complexed with an excess of EDTA and the surplus EDTA is titrated with lead nitrate solution at pH 5.0–6.0 (hexamine), using xylenol orange as indicator. An excess of 1,10-phenanthroline is then added and the EDTA released from the Cd-EDTA complex is titrated with standard lead nitrate solution. Results are obtained for 1.5–57 mg of Cd with relative errors ≤0.90% and standard deviations ≤0.06 mg. Cu(II), Co(II), Hg(II), Ni(II), Zn(II), Pd(II), Tl(III), Au(III) and Sn(IV) interfere, but can be easily masked. The method is applied for the determination of cadmium in synthetic alloy solutions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. K. Huber,Z. Elektrochem. 1958,62, 675.

    Google Scholar 

  2. P. E. Lake, E. J. Casey,J. Electrochem. Soc. 1958,105, 52.

    Google Scholar 

  3. N. I. Sax (ed.),Dangerous Properties of Industrial Materials, 3rd Ed., Reinhold, New York, 1968.

    Google Scholar 

  4. C. H. Gray (ed.),Laboratory Handbook of Toxic Agents, 2nd Ed., Royal Institute of Chemistry, London, 1966.

    Google Scholar 

  5. F. M. Turner,Cadmium Poisoning, Atomic Energy Research Establishment, Harwell, U. K. Ref. Med/M17., 1957.

    Google Scholar 

  6. A. I. Vogel,A Textbook of Quantitative Inorganic Analysis, 5th Ed., Longmans, London, 1989, p. 58.

    Google Scholar 

  7. S. Kotrly, L. Sucha,Handbook of Chemical Equilibria in Analytical Chemistry, Ellis Horwood, Chichester, 1985, p. 189.

    Google Scholar 

  8. B. Ramachandra, B. Narayana, B. Muralidhara Rao, C. H. R. Nambiar, K. S. Bhat, B. Mathew,Anal. Proc. 1995,32, 379.

    Google Scholar 

  9. B. Murlidhara Rao, B. Narayana, K. S. Bhat,Mikrochim. Acta 1994,117, 109.

    Google Scholar 

  10. B. Muralidhara Rao, B. Narayana, K. S. Bhat, B. Mathew,Mikrochim. Acta 1995,118, 63.

    Google Scholar 

  11. B. Mathew, B. Muralidhara Rao, B. Narayana,Mikrochim. Acta 1995,118, 197.

    Google Scholar 

  12. Muralidhara Rao, B. Narayana,Turkish J. Chem. 1993,17, 138.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ramachandra, B., Narayana, B. Indirect complexometric determination of cadmium(II) using 1,10-phenanthroline as selective masking agent. Mikrochim Acta 126, 223–225 (1997). https://doi.org/10.1007/BF01242324

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01242324

Key words

Navigation