Skip to main content
Log in

Magnetic resonance imaging of cyclodialysis clefts

  • Short Communication
  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

• Background: Our purpose was to determine whether cyclodialysis clefts can be imaged with magnetic resonance imaging (MRI). • Methods: Surgical cyclodialysis clefts extending approximately 3 clock hours were created in four New Zealand white rabbits. Eyes were scanned with an ocular MRI coil. Images obtained after intravenous gadolinium, topical godalinium, and gadolinium injected into the cleft were compared to images obtained without contrast. Two human eyes were also scanned for cyclodialysis clefts with MRI. • Results: Direct injection of gadolinium into the suprachoroid space yielded definitive localization and delineation of the cyclodialysis cleft. Cyclodialysis clefts could also be imaged following enhancement with topical or intravenous gadolinium. Without contrast medium, the clefts could not be clearly identified in rabbits. In a patient with hypotony and choroidal effusion following cataract surgery, a cyclodialysis cleft and enhancement of the suprachoroidal space were found with intravenous administration of gadolinium. MRI from a patient with a trabeculo-suprachoroidal shunt also demonstrated gadolinium enhancement of the suprachoroidal space. • Conclusion: Cyclodialysis clefts can be imaged using gadolinium-enhanced MRI in rabbits and humans.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Bond JB, Haik BG, Mihara F, Gupta KL (1991) Magnetic resonance imaging of choroidal melanoma with and without gadolinium contrast enhancement. Ophthalmology 98:459–466

    PubMed  Google Scholar 

  2. Cheng H-M (1991) Magnetic resonance imaging of the human eye in vivo. Optom Vis Sci 68:976–980

    PubMed  Google Scholar 

  3. Karwatowski WS, Weinreb RN (1994) Imaging of cyclodialysis cleft by ultrasound biomicroscope. (letter) Am J Ophthalmol 117:541–534

    PubMed  Google Scholar 

  4. Lee KY, Lashkari K, Kwong KK, Cheng H-M (1992) Magnetic resonance imaging of the aqueous flow in eyes implanted with the trabeculo-suprachoroidal glaucoma seton. Invest Ophthalmol Vis Sci [Suppl] 33:948

    Google Scholar 

  5. Ormerod LD, Baerveldt G, Sunalp MA, Riekhof FT (1991) Management of the hypotonous cyclodialysis cleft. Ophthalmology 98: 1384–1393

    PubMed  Google Scholar 

  6. Rubin PAD, Bilyk JR, Shore JW, Sutula FC, Cheng H-M (1994) Magnetic resonance imaging of the lacrimal drainage system. Ophthalmology 101: 235–243

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

The authors have no proprietary interest in the companies or products mentioned in this article

Rights and permissions

Reprints and permissions

About this article

Cite this article

Johnson, S.M., Cheng, HM., Pineda, R. et al. Magnetic resonance imaging of cyclodialysis clefts. Graefe's Arch Clin Exp Ophthalmol 235, 468–471 (1997). https://doi.org/10.1007/BF00947068

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00947068

Keywords

Navigation