Signal rise time of the magnetic bolometer

  • Innovative Approaches
  • Published:
Journal of Low Temperature Physics Aims and scope Submit manuscript

Abstract

We present measurements of the temperature dependent signal rise time τS and discuss a model for calculating τS(T). The bolometer consists of a paramagnetic sample and an absorber. The lattice is heated up by absorbing α - particles, and the relaxation of the magnetization is measured with a SQUID. With decreasing temperatures τS first increases as τ1∼1/T, but then decreases strongly. At 30 mK it is reduced by orders of magnitude compared with τ1. This result is in agreement with a theoretical model which takes into account the heat capacities of the lattice, the resonant phonons, the spins, and thermal resistances between these capacities. Under the condition of the bottleneck effect τS is found to be proportional to T3. At low temperatures the lowest values of τS of 2 ms may already be limited by the Kapitza resistance. These are the first measurements of the spin-lattice relaxation times with the energy being transferred from the lattice to the spins.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. E. Umlauf and M. Bühler, inLow Temperature Detectors for Neutrinos and Dark Matter IV, ed. by N. E. Booth and G. L. Salmon (Edition Frontieres) 1992, p.229.

  2. M.Bühler and E.Umlauf, ibid, p. 237.

  3. E. Umlauf and M. Bühler, inSPIE: EKV, X-Ray and Gamma-Ray Instruments for Astronomy III, Vol. 1743, edited by O.H.W. Siegmund (SPIE — The Int. Society for Optical Engineering, San Diego) 1992, p. 391.

    Google Scholar 

  4. D. Drung, R. Cantor, M. Peters, T. Ryhänen and H. Koch,IEEE Trans. Magn. MAG-27, 1991, p. 3001.

    Google Scholar 

  5. M. Bühler, E. Umlauf, D. Drung and H. Koch inProc. of the 4th Int. Conf. on Superconducting Quantum Devices and their Applications edited by H. Koch and H. Lübbig, (Springer Verlag) 1992.

  6. W. Gräper inLANDOLT-BÖRNSTEIN, Neue Serie III/4b edited by K.H. Hellwege and A.M. Hellwege (Springer Verlag) 1970, p. 791.

  7. A. Abragam and B. Bleaney inElectron Paramagnetic Resonance of Transition Ions (Clarendon Press, Oxford) 1970.

    Google Scholar 

  8. M.Bühler, T.Fausch and E. Umlauf, to be published in Europhysics letters.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fausch, T., Bühler, M. & Umlauf, E. Signal rise time of the magnetic bolometer. J Low Temp Phys 93, 703–708 (1993). https://doi.org/10.1007/BF00693499

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00693499

PACS numbers

Navigation