The immunoscintigraphic detection of tumour foci < 1 cm in diameter fails even with single photon emission tomography (SPET) owing to low contrast against background activity. In an attempt to improve detection of macroscopically invisible tumour spread, intraoperative scintimetry (IOSM) with a hand-held gamma-probe was performed in addition to SPET 24–30 and 41–48 h after injection of the technetium-99m carcinoembryonic antigen (CEA MoA) on 12 patients with colorectal carcinoma and 3 patients with different neoplastic and inflammatory diseases. Tumour specimens were measured in vitro in a gamma well counter. For comparison, the presence and amount of CEA in the tumour cells were evaluated immunohistochemically. After modification, the gamma-probe originally designed for iodine-131 was 20 times more sensitive; activities of 99Tc located close to the collimator hole were measured with absolute sensitivity of 100 cps = 2.5 kBq 99mTc. The unfavourably high background activity affected both the in vitro and in vivo analysis: SPET results had been considered positive in 8 of 15 cases. In vitro tumour/non-tumour (t/nt) ratios > 2.0 were found in 4 cases. In vivo IOSM resulted in t/nt ratios >2.0 in only 3 patients. In most cases, there was no coincidence of elevated t/nt ratios from the different methods. A correlation was derived between positive immunoscintimetric in vitro findings and immunohistochemically proven interstitial localization of CEA in tumor cells. In conclusion, the measurement technique of IOSM seems adequate, but clinical success will depend on a more specific enrichment of MoA in tumour tissue. Future in vivo studies should be performed mainly in cases with a positive immunohistochemistry (interstitial CEA localization) result for the primary tumour.
Similar content being viewed by others
References
Abdel-Nabi HH, Schwartz AN, Goldfogel G, et al. (1988) Colorectal tumors: scintigraphy with In111 anti-CEA monoclonal antibody and correlation with surgical, histopathologic, and immunohistochemical findings. Radiology 166:747–752
Bares R, Fass J, Weiller G, et al. (1989) Klinische Bedeutung der Immunszintigraphie für Diagnose und Therapie gastrointestinaler Malignome. Onkologie 12 [Suppl]:13–18
Baum RP, Lorenz M, Hör G (1987) Radioimmunszintigraphie bei kolorektalen Karzinomen — Stellenwert in der Rezidivdiagnostik nach 2 Jahren klinischer Erfahrung. Der Nuklearmediziner 3 (10):219–234
Baum RP, Lorenz M, Hertel A, et al. (1989) Erfolgreiche immunszintigraphische Tumordetektion mit 99mTc markierten monoklonalen Anti-CEA-Antikörpern. Onkologie 12 [Suppl]: 26–29
Bertoglio F, Percivale P, Schenone F, et al. (1989) The intraoperative detection of colorectal cancer by radiolabelled B72.3 I125 monoclonal antibody (mab) and radioimmunoguided surgery. Fifth Symposium über Tumormarker, Hamburg, 4–6 December 1989 (lecture)
Bosslet K, Steinstrdsser A, Schwarz A, et al. (1988) Quantitative considerations supporting the irrelevance of circulating serum CEA for the immunoscintigraphic visualization of CEA expressing carcinomas. Eur J Nucl Med 14:523–528
Chatal JF, Saccavini J-C, Fumoleau P, et al. (1984) Immunoscintigraphy of colon carcinoma. J Nucl Med 25:307–314
Goodwin DA, Meares CF, McCall MJ, et al. (1988) Pre-targeted immunoscintigraphy of murine tumors with In111 labelled bifunctional haptens. J Nucl Med 29:226–234
Hnatwoich DJ, Virzi F, Rusckowski M (1987) Investigations of avidin and biotin for imaging applications. J Nucl Med 28:1294–1302
Hölting T, Schlag P, Steinbdcher M, et al. (1989) The value of immunoscintigraphy for the operative retreatment of colorectal cancer. Cancer 64:830–833
Jäger W, Paterok E, Feistel H (1988) Resektion geleited durch Antikörper — REGAJ — Nachweis von Ovarialkarzinomen nach vorheriger Immunszintigraphie. Tumor Diagnostik Therapie 9:191–195
Kramer EL, Sanger JJ, Walsh C, et al. (1988) Contribution of SPELT to imaging of gastrointestinal adenocarcinoma with In111 labelled anti-CEA monoclonal antibody. AJR 151:697–703
Kroiss A, Tuchmann A, Schüller J, et al. (1989) Immunszintigraphische Tumordiagnostik mit Anti-CEA-Antikörpern (Tc-99m MAK BW 431/26). Wien Klin Wochenschr 101 (18):621–626
Lind P, Langsteger W, Költringer P, et al. (1989) Tc99m-labelled monoclonal anticarcinoembryonic antigen antibody (BW 431/26). Scand J Gastroenterol 24:1205–1211
Mach JP, Carrel S, Forni M, et al. (1980) Tumor localization of radiolabeled antibodies against carcinoembryonic antigen in patients with carcinoma. N Engl J Med 303:5–10
Martin EW, Mojzisik CM, Hinkle GH, et al. (1988) Radioimmunoguided surgery using monoclonal antibody. Am J Surg 156:386–392
Montz R, Klapdor R, Rothe B, et al. (1986) Immunoscintigraphy and radioimmunotherapy in patients with pancreatic carcinoma. Nucl Med 25:239–244
Nieroda CA, Mojzisik C, Sardi A, et al. (1989) Staging of carcinoma of the breast using a hand-held gamma detecting probe and monoclonal antibody B72.3. Surg Gynecol Obstet 36:35–41
Oehr P, Schultes B, Liu Q, Altreuther M, Bockisch A, Biersack HJ (1990) Standardized phantom evaluation of hand-guided probes for detection or radioactivity during surgery. In: Klapdor R (ed) Recent results in tumor diagnosis and therapy. W. Zuckschwerdt, Munich
Riva P, Moscatelli G, Paganelli G, et al. (1988) Antibody-guided diagnosis: an Italian experience on CEA-expressing tumors. Int J Cancer [Suppl] 2:114–120
Sardi A, Workman M, Mojzisik C, et al. (1989) Intra-abdominal recurrence of colorectal cancer detected by radioimmunoguided surgery (Rigs system). Arch Surg 124:55–59
Schlag P, Hölting T, Steinbächer M, et al. (1987) Zur derzeitigen Rolle der Immunszintigraphie für die operative Rezidivtherapie colorectaler Carcinome. Chirurg 58:594–596
Schwarz A, Steinsträsser A (1987) A novel approach to Tc99m labelled monoclonal antibodies. J Nucl Med 28:721
Siccardi AG, Buraggi GL, Callegoro L, et al. (1989) Immunoscintigraphy of adenocarcinomas by means of radiolabelled F(ab′)2 fragments of anti-carcinoembryonic antigen monoclonal antibody: a multicenter study. Cancer Res 49:3095–3103
Sickle-Santanello BJ, O'Dwyer PJ, Mojzisik C, et al. (1987) Radioimmunoguided surgery using the monoclonal antibody B 72.3 in colorectal tumors. Dis Colon Rectum 30:761–764
Tuttle SE, Jewell SD, Mojzisik CM, et al. (1988) Intraoperative radioimmunolocalization of colorectal carcinoma with a handheld gamma probe and MAb B72.3: comparison of in vivo gamma probe counts with in vitro MAb radiolocalization. Int J Cancer 42:352–358
Vaugham ATM, Anderson P, Dykes PW, et al. (1987) Limitations to the killing of tumors using radiolabelled antibodies. BJR 60:567–578
Author information
Authors and Affiliations
Additional information
Offprint requests to: M. Reuter
Rights and permissions
About this article
Cite this article
Reuter, M., Mortz, R., de Heer, K. et al. Detection of colorectal carcinomas by intraoperative RIS in addition to preoperative RIS: surgical and immunohistochemical findings. Eur J Nucl Med 19, 102–109 (1992). https://doi.org/10.1007/BF00184124
Issue Date:
DOI: https://doi.org/10.1007/BF00184124