Abstract
This paper deals with the fault and abnormality analysis in PV array, monitoring the grid-tied hybrid micro-grid current. Firstly, a hybrid system has been built-in software, and a series arc fault has been inserted. The micro-grid current has been recorded and analyzed using Stockwell transform-based statistical parameter monitoring, and optimized parameter has been selected for fault analysis in the system. Depending on the variation in the statistical parameter values, features have been extracted. A logic has been proposed at the end for abnormality assessment in the system with practical validation of the work using field data.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Jayachandran M, Ravi G (2017) Design and optimization of hybrid microgrid system. Energy Proceedings, vol 117. Elsevier, pp 95–103. Available: https://www.sciencedirect.com/sciencedirect.com/science/article/pii/S1876610217323184
Kabalci E, Bayindir R, Hossain E (2017) Hybrid microgrid testbed involving wind/solar/fuel cell plants: a design and analysis test bed. Presented at ICRERA. Available: https://ieeexplore.ieee.org/document/7016511
Aisheh AA (2018) Hybrid solar/wind micro-grid systems. Presented at conventional and sustainable energies. Available: https://www.omicsonline.org/conference-proceedings/2090-4541-C1-050-005.pdf
Traore A, Elgothamy H, Zohdy MA (2018) Optimal sizing of solar/wind hybrid off-grid microgrids using an enhanced genetic algorithm. J Power Energy Eng 6:64–77. Available: https://file.scirp.org/pdf/JPEE_2018053014523053.pdf
Li J, Wei W, Xiang J (2012) A simple sizing algorithm for stand-alone PV/wind/battery hybrid microgrids. Energy 5:5307–5323. Available: https://www.mdpi.com/1996-1073/5/12/5307/energies-05-05307.pdf
Ruban MAM, Rajasekaran GM, Rajeswari N (2015) Implementation of energy management system to PV-wind hybrid power generation system for DC microgrid applications. Int Res J Eng. Tech 2(8):204–210. Available: https://www.irjet.net/archives/V2/i8/IRJET-V2I835.pdf
Habibullah M, Mahmud K, Kocar G, Islam AKMS (2017) Economic challenges of hybrid microgrid: an analysis and approaches for rural electrification. Presented at AIP. Available: https://aip.scitation.org/doi/10.1063/1.4984672
Sawlw Y, Gupta SC, Bore AK (2016) PV-wind hybrid system: a review with case study. Cogent Eng 3(1):1–31. Available: https://www.tandfonline.com/doi/pdf/10.1080/23311916.2016.1189305?needAccess=true
Priyadharshini E, Meena S (2015) Optimization of hybrid solar wind power by implementing microgrid control and controlling pollution by reducing. Int J Emerg Technol Comput Sci Electron 13(1):203–208. Available: http://www.ijetcse.com/wp-content/plugins/ijetcse/file/upload/docx/646OPTIMIZATION-OF-HYBRID-SOLAR-WIND-POWER-BY-IMPLEMENTING-MICROGRID-CONTROL-AND-CONTROLLING-POLLUTION-BY-REDUCING-CO-pdf.pdf
Acharya S (2016) Simulation and control of PV-wind-hydro hybrid renewable energy system and possibility I Nepal. Int J Sci Eng Res 7(8):1540–1555. Available: https://www.ijser.org/researchpaper/Simulation-and-Control-of-Pv-Wind-HydroHybrid-Renewable-Energy-System-and-Possibility-in-Nepal.pdf
Lauria D, Lamb S, Aisheh AA (2016) Designing stand-alone microgrid hybrid solar/wind energy systems and grid-connected smartgrid hybrid solar/wind energy systems. Presented at IAJC-ISAM. Available: http://cd16.iajc.org/wp-content/uploads/Camera-ready-papers/070-x-16___Designing%20a%20Microgrid%20Hybrid%20Solar-Wind%20Energy%20System%20_REVISDED2_Abu_Aisheh_Lamb_Lauria.pdf
Sharif MSE, Khan MMZ, Moniruzzaman M, Bose A (2017) Design, simulation and stability analysis of wind-PV-diesel hybrid power system using ETAP. Am J Mod Energy 3(6):121–130. Available: http://www.sciencepublishinggroup.com/journal/paperinfo?journalid=363&doi=10.11648/j.ajme.20170306.12
Kar Ray D, Chattopadhyay S, Sengupta S (2018) Fault diagnosis in isolated renewable energy conversion system using skewness and Kurtosis assessment. In: Advances in intelligent systems and computing, pp 57–71. Available: https://link.springer.com/chapter/10.1007/978-3-319-74808-5_7
Kar Ray D, Chattopadhyay S, Sengupta S (2017) Multi-resolution analysis based line to ground fault discrimination in standalone wind energy conversion system in harmonic environment. In: Lectures on modelling and simulation; a selection from AMSE, pp 139–150. Available: http://amsemodelling.com/publications/lectures_on_modeling_and_simulation/calcutta_14.pdf
Ray DK, Sarkar G, Paul P, Haldar R, Ghoshal S, Sadhukhan S, Chattopadhyay S (2017) Fault detection in wind energy conversion system using multi-resolution analysis of discrete wavelet transform. C+ CA Program Eng Sci 42(1), pp 26–31. ISSN: 0045–6152
Wang L, Vo QS, Prokhorov AV (2018) Stability improvement of a multimachine power system connected with a large-scale hybrid wind-photovoltaic farm using a supercapacitor. IEEE Trans Ind App 54(1), pp 50–60. ISSN: 1939–9367
Arabali A, Ghofrani M, Amoli ME, Fadali MS (2014) Stochastic performance assessment and sizing for a hybrid power system of solar/wind/energy storage. IEEE Trans Sustain Energy 5(2):363–371. ISSN: 1949–3037
Kim SK, Jeon JH, Cho CH, Ahn JB, Kwon SH (2008) Dynamic modeling and control of a grid-connected hybrid generation system with versatile power transfer. IEEE Trans Ind Elec 55(4), pp 1677–1688. ISSN: 1557–9948
Feng L, Zhang J, Li G, Zhang B (2016) Cost reduction of a hybrid energy storage system considering correlation between wind and PV power. Prot Cont Mod Power Syst 1-9. https://doi.org/10.1186/s41601-016-0021-1
Adefarati T, Bansal RC, Justo JJ (2017) Techno-economic analysis of a PV-wind-battery-diesel standalone power system in a remote area. J Eng IET 740–744. ISSN: 2051–3305
George NV (2009) S-transform: time frequency analysis and filtering. M.Sc. thesis, EE., NIT., Rour., Orissa
Technical data: 15.12 kWp PVRT system, Sterlite Power, India
Acknowledgements
We are grateful to Mr. Raktim Basak, Associate Manager, Sterlite Power, for providing the necessary data for analysis purpose.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Ray, D.K., Das, D., Shah, O.P., Singh, S.K., Chattopadhyay, S. (2021). Condition Monitoring of PV-Wind System Using Stockwell Transform. In: Nath, V., Mandal, J.K. (eds) Proceedings of the Fourth International Conference on Microelectronics, Computing and Communication Systems. Lecture Notes in Electrical Engineering, vol 673. Springer, Singapore. https://doi.org/10.1007/978-981-15-5546-6_23
Download citation
DOI: https://doi.org/10.1007/978-981-15-5546-6_23
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-15-5545-9
Online ISBN: 978-981-15-5546-6
eBook Packages: EngineeringEngineering (R0)