Skip to main content

Carbon on poly(ε-caprolactone) (PCL) Ink-jet Printed Sensor for Monitoring Cell Cultures of Myoblasts

  • Conference paper
  • First Online:
EMBEC & NBC 2017 (EMBEC 2017, NBC 2017)

Abstract

Nowadays techniques for sensitive non-invasive, real-time monitoring of cell differentiation and maturation are highly demanded. In light of this, the development of electrochemical printed sensors impedance-based could represent a promising tool. In the present work, we developed 2D ink-jet printed sensors for myoblasts adhesion monitoring, using carbon-based ink on a substrate consisting in non-woven electrospun mats made in crosslinked poly(ε-caprolactone) (PCL). First of all, sensors printability was optimized and the biocompatibility tested. In order to determine the possibility to employ the prepared systems as scaffolds for dynamic cellular cultures, the mechanical response of the PCL scaffold was evaluated through the application of cyclic deformation tests. After that, electrical characterization of ink and substrate was performed, followed by electrochemical impedance-based measurements to evaluate myoblasts adhesion. Biocompatibility assessment showed good results for both carbon and PCL. Mechanical tests findings suggested that a training of 50 cycles and a proper value of strain should be applied before the cell seeding, in order to ensure a subsequent controlled strain amplitude. The sensorized scaffold allowed us to correlate cell adhesion with an increase of impedance module, in agreement with biocompatibility testing. Thus, this first preliminary testing suggested that this non-invasive impedance spectroscopy-based measurement system can be used for sensitive monitoring of cells adhesion, in static and moreover, as suggested from mechanical characterization, in dynamic conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • 1. Seidel D, Obendorf J, Englich B et al. (2016) Impedimetric real-time monitoring of neural pluripotent stem cell differentiation process on microelectrode arrays. Biosens Bioelectron 86:277-86. doi: 10.1016/j.bios.2016.06.056.

  • 2. Zhang X, Ju H, Wang J (2008) Electrochemical Sensors, Biosensors and Their Biomedical Applications. Elsevier, Amsterdam.

    Google Scholar 

  • 3. Giaever I, Keese CR (1984) Monitoring fibroblast behavior in tissue culture with an applied electric field. Proc Natl Acad Sci U S A 81(12):3761-4.

    Google Scholar 

  • 4. Qiu Y, Liao R, Zhang X (2009) Impedance-based monitoring of ongoing cardiomyocyte death induced by tumor necrosis factor-alpha. Biophys J 96(5):1985-91. doi: 10.1016/j.bpj.2008.11.036.

  • 5. Scoutaris N, Ross S, Douroumis D (2016) Current Trends on Medical and Pharmaceutical Applications of Inkjet Printing Technology. Pharm Res. 33(8):1799-816. doi:10.1007/s11095-016-1931-3. Review.

  • 6. Gwak SJ, Bhang SH et al. (2008) The effect of cyclic strain on embryonic stem cell-derived cardiomyocytes. Biomaterials 29(7):844-56.

    Google Scholar 

  • 7. Merlettini A, Pandini S, Agnelli S et al. (2016) Facile fabrication of shape memory poly(ε-caprolactone) non-woven mat by combining electrospinning and sol-gel reaction, RSC Adv 43964-43974.

    Google Scholar 

  • 8. Astashkina A, Mann B, Grainger DW (2012) A critical evaluation of in vitro cell culture models for high-throughput drug screening and toxicity. Pharmacol Ther 134(1):82-106. doi: 10.1016/j.pharmthera.2012.01.001. Review.

  • 9. Tonello S, Lopomo N F, Serpelloni M et al. (2016) Preliminary Study of Inkjet Printed Sensors for Monitoring Cell Cultures. Procedia Engineering 168 (2016) 30th Eurosensors Conference, Budapest, Hungary, 2016, pp 578 – 581

    Google Scholar 

  • 10. Schwan HP (1992) Linear and nonlinear electrode polarization and biological materials. Ann Biomed Eng 20(3):269-88.

    Google Scholar 

  • 11. Onaral B, Schwan HP (1982) Linear and nonlinear properties of platinum electrodepolarisation. Part 1: frequency dependence at very low frequencies. Med Biol Eng Comput 20(3):299-306.

    Google Scholar 

  • 12. Schmelter M, Ateghang B, Helmig S et al. (2006) Embryonic stem cells utilize reactive oxygen species as transducers of mechanical strain-inducedcardiovascular differentiation. FASEB J 20(8):1182-4.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mariagrazia Marziano .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this paper

Cite this paper

Marziano, M. et al. (2018). Carbon on poly(ε-caprolactone) (PCL) Ink-jet Printed Sensor for Monitoring Cell Cultures of Myoblasts. In: Eskola, H., Väisänen, O., Viik, J., Hyttinen, J. (eds) EMBEC & NBC 2017. EMBEC NBC 2017 2017. IFMBE Proceedings, vol 65. Springer, Singapore. https://doi.org/10.1007/978-981-10-5122-7_196

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-5122-7_196

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-5121-0

  • Online ISBN: 978-981-10-5122-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics