Skip to main content

Comparative Study of Harmonics and Total Harmonic Distortion of Five-Phase Inverter Drive with Five-Phase Multilevel Inverter Drive Using Simulink/MATLAB

  • Chapter
  • First Online:
Advances in Power Systems and Energy Management

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 436))

  • 1243 Accesses

Abstract

Harmonics are created in the output of the Inverters due to nonlinear loads. These harmonics not only causes excessive heat in the devices or appliances used in the daily life of human being, but also reduces the life period of the appliances. This reduction of harmonics in such system has become great concern for the engineers. Multilevel inverter technology has proved to give improved harmonic performance. This paper presents simulation of harmonic analysis in five-phase two-level inverter and five-phase multilevel (three level). It has been found that the total harmonic distortion (THD) is less in case of five-phase three-level inverter.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 279.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Patomaki, L., Forsti, J., Nokso-Koivisto, V.-M., Jokinen, Y., Lansimies, E.: On line recording and analysis of the ECG in ambulatory patients. Comput. Cardiol. 173–175 (1981)

    Google Scholar 

  2. Thakor, N.V., Webster, J.G., Tompkins, W.J.: Design, implementation, and evaluation of a microcomputer-based portable arrhythmia monitor. Med. Biol. Eng. Comput. 22, 151–159 (1984)

    Article  Google Scholar 

  3. Mark, R.G., Moody, G.B., Olson, W.H., Peterson, P.S., Schulter, S.K., Walters, J.B., Jr.: Real-time ambulatory arrhythmia analysis with a microcomputer. Comput. Ardiol. 57–62 (1979)

    Google Scholar 

  4. Pahlm, O., Sornmo, L.: Software QRS detection in ambulatory monitoring—a review. Med. Biol. Eng. Comput. 22, 289–297 (1984)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Manjesh .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Manjesh, Hasitha, K., Bhoi, A.K., Garg, A. (2018). Comparative Study of Harmonics and Total Harmonic Distortion of Five-Phase Inverter Drive with Five-Phase Multilevel Inverter Drive Using Simulink/MATLAB. In: Garg, A., Bhoi, A., Sanjeevikumar, P., Kamani, K. (eds) Advances in Power Systems and Energy Management. Lecture Notes in Electrical Engineering, vol 436. Springer, Singapore. https://doi.org/10.1007/978-981-10-4394-9_4

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-4394-9_4

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-4393-2

  • Online ISBN: 978-981-10-4394-9

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics