Abstract

Cone-beam CT (CBCT) and digital tomosynthesis are becoming interesting tools for paranasal sinus imaging. In present study, the effective dose of these new techniques was compared with the effective dose of multi slice CT (MSCT) acquisitions.

An anthropomorphic Rando phantom was fitted with 156 calibrated thermoluminescent dosimeters (TLD) in positions representative for the radiosensitive organs and tissues according to the 2007 recommendations of the International Commission of Radiological Protection. CBCT (Imaging Sciences International, I-CAT), digital tomosynthesis (GE, Definium 8000/VolumeRAD), low-dose and standard dose MSCT (GE, Lightspeed 16) acquisitions of the Rando phantom were obtained. For all imaging systems, the Rando phantom was positioned and exposed in a similar way as for patient paranasal sinus imaging on that specific system. Afterwards exposure, TLDs were read out and TLD readings were converted into organ doses.

Independent of the applied imaging techniques, the salivary glands, the brain and the thyroid are receiving the highest equivalent doses for the paranasal sinus imaging. The effective dose for the CBCT and the digital tomosynthesis examinations were 30μSv and 65 μSv respectively. For the MSCT examination, effective doses of 200μSv and 1400 μSv were found for the low-dose and the standard CT protocol.

Paranasal sinus imaging with CBCT and digital tomosynthesis showed a large dose reduction compared to low-dose and standard MSCT. When comparing the two new imaging techniques, CBCT could acquire high quality images at less than half the dose of the digital tomosynthesis system.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Bacher, K., Mermuys, K., Casselman, J., Thierens, H. (2009). Evaluation of Effective Patient Dose in Paranasal Sinus Imaging: Comparison of Cone Beam CT, Digital Tomosynthesis and Multi Slice CT. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/3. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03902-7_129

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03902-7_129

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03901-0

  • Online ISBN: 978-3-642-03902-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics