Abstract
Irritant and allergic occupational dermatitis in bath attendants can be induced by water, disinfectants, sunscreens, swimming clothes, or equipment.
Especially repeated and prolonged wet work causes skin irritation and impairs the skin barrier function.
Contact dermatitis to disinfectants is rarely observed and mainly caused by chlorinated or brominated by-products in the swimming pool water, such as trihalomethanes (e.g., trichloromethane, chloroform), haloamines, haloacetic acids, and haloketones or disinfectants used to disinfect pool edges, showers, bathrooms, or pediluvia, such as sodium hypochloride, aldehydes, and quaternary ammonium compounds.
Contact dermatitis associated with disinfectants used in swimming pools are rather due to irritancy, but may also be caused by true sensitization.
Urticaria induced by swimming in pools can be cold-induced urticaria, aquagenic urticaria, or contact urticaria to chlorinated water.
Rare causes of occupational dermatoses in bath attendants are skin infections due to pathogens in the pool water, aquagenic pruritus, or skin cancer induced by exposure to UV-light during outdoor activities.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Alomar A, Vilaltella I (1985) Contact dermatitis to dibutylthiourea in swimming goggles. Contact Dermatitis 13(5):348–349
Bentley B 2nd (1993) Cold-induced urticaria and angioedema: diagnosis and management. Am J Emerg Med 11(1):43–46
Blauvelt A, Duarte AM et al (1992) Pool palms. J Am Acad Dermatol 27(1):111
Cammann K, Hubner K (1995) Trihalomethane concentrations in swimmers’ and bath attendants’ blood and urine after swimming or working in indoor swimming pools. Arch Environ Health 50(1):61–65
Caro J, Gallego M (2007) Assessment of exposure of workers and swimmers to trihalomethanes in an indoor swimming pool. Environ Sci Technol 41(13):4793–4798
Choong KY, Roberts LJ (1999) Molluscum contagiosum, swimming and bathing: a clinical analysis. Australas J Dermatol 40(2):89–92
Chu H, Nieuwenhuijsen MJ (2002) Distribution and determinants of trihalomethane concentrations in indoor swimming pools. Occup Environ Med 59(4):243–247
Dooms-Goossens A, Gevers D et al (1983) Allergic contact urticaria due to chloramine. Contact Dermatitis 9(4):319–320
Fisher AA (1987) Contact dermatitis to diving equipment, swimming pool chemicals, and other aquatic denizens. Clin Dermatol 5(3):36–40
Fisher AA (1988) Swimming pool granulomas due to Mycobacterium marinum: an occupational hazard of lifeguards. Cutis 41(6):397–398
Fisher AA (1993) Aquagenic pruritus. Cutis 51(3):146–147
Fitzgerald DA, Wilkinson SM et al (1995) Spa pool dermatitis. Contact Dermatitis 33(1):53
Frances AM, Fiorenza G et al (2004) Aquagenic urticaria: report of a case. Allergy Asthma Proc 25(3):195–197
Geller AC, Glanz K et al (2001) Impact of skin cancer prevention on outdoor aquatics staff: the pool cool program in Hawaii and Massachusetts. Prev Med 33(3):155–161
Goette DK (1984) Raccoon-like periorbital leukoderma from contact with swim goggles. Contact Dermatitis 10(3):129–131
Gould D (1983) Dermatoses associated with brominated swimming pools. Br Med J (Clin Res Ed) 287:913
Gustafson TL, Band JD et al (1983) Pseudomonas folliculitis: an outbreak and review. Rev Infect Dis 5(1):1–8
Hall DM, McCarty F et al (2009) Lifeguards’ sun protection habits and sunburns: association with sun-safe environments and skin cancer prevention program participation. Arch Dermatol 145(2):139–144
Heitkemper T, Hofmann T et al (2010) Aquagenic pruritus: associated diseases and clinical pruritus characteristics. J Dtsch Dermatol Ges 8(10):797–804
Hostynek JJ, Patrick E et al (1989) Hypochlorite sensitivity in man. Contact Dermatitis 20(1):32–37
Jacobson JA (1985) Pool-associated Pseudomonas aeruginosa dermatitis and other bathing-associated infections. Infect Control 6(10):398–401
Kanerva L, Alanko K et al (1997) Occupational allergic contact urticaria from chloramine-T solution. Contact Dermatitis 37(4):180–181
Kelsall HL, Sim MR (2001) Skin irritation in users of brominated pools. Int J Environ Health Res 11(1):29–40
Loughney E, Harrison J (1998) Irritant contact dermatitis due to 1-bromo-3-chloro-5,5-dimethylhydantoin in a hydrotherapy pool. Risk assessments: the need for continuous evidence-based assessments. Occup Med (Lond) 48(7):461–463
Maibach H (1975) Scuba diver facial dermatitis: allergic contact dermatitis to N-isopropyl-N-phenylpara-phenylenediamine. Contact Dermatitis 1(5):330
Massin N, Bohadana AB et al (1998) Respiratory symptoms and bronchial responsiveness in lifeguards exposed to nitrogen trichloride in indoor swimming pools. Occup Environ Med 55(4):258–263
Morgan J (1983) Dermatoses associated with brominated swimming pools. Br Med J (Clin Res Ed) 287:913
Neering H (1977) Contact urticaria from chlorinated swimming pool water. Contact Dermatitis 3(5):279
Osmundsen PE (1978) Contact dermatitis due to sodium hypochlorite. Contact Dermatitis 4(3):177–178
Pardo A, Nevo K et al (2007) The effect of physical and chemical properties of swimming pool water and its close environment on the development of contact dermatitis in hydrotherapists. Am J Ind Med 50(2):122–126
Penny PT (1991) Hydrotherapy pools of the future–the avoidance of health problems. J Hosp Infect 18(Suppl A):535–542
Penso-Assathiany D, Flahault A et al (1999) Warts, swimming pools and atopy: a case control study conducted in a private dermatology practice. Ann Dermatol Venereol 126(10):696–698
Rycroft RJ, Penny PT (1983) Dermatoses associated with brominated swimming pools. Br Med J (Clin Res Ed) 287(6390):462
Sasseville D, Geoffrion G et al (1999) Allergic contact dermatitis from chlorinated swimming pool water. Contact Dermatitis 41(6):347–348
Scheuer E, Warshaw E (2006) Sunscreen allergy: a review of epidemiology, clinical characteristics, and responsible allergens. Dermatitis 17(1):3–11
Sibbald RG, Black AK et al (1981) Aquagenic urticaria: evidence of cholinergic and histaminergic basis. Br J Dermatol 105(3):297–302
Siebenhaar F, Degener F et al (2009) High-dose desloratadine decreases wheal volume and improves cold provocation thresholds compared with standard-dose treatment in patients with acquired cold urticaria: a randomized, placebo-controlled, crossover study. J Allergy Clin Immunol 123(3):672–679
Treudler R, Tebbe B et al (2002) Familial aquagenic urticaria associated with familial lactose intolerance. J Am Acad Dermatol 47(4):611–613
Tuyp E, Mitchell JC (1983) Scuba diver facial dermatitis. Contact Dermatitis 9(4):334–335
Valsecchi R, Cassina GP et al (1985) Tego dermatitis. Contact Dermatitis 12(4):230
van Joost T, Habets JM et al (1987) Sodium hypochlorite sensitization. Contact Dermatitis 16(2):114
Zwiener C, Richardson SD et al (2007) Drowning in disinfection byproducts? Assessing swimming pool water. Environ Sci Technol 41(2):363–372
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this entry
Cite this entry
Brans, R. (2012). Bath Attendants. In: Rustemeyer, T., Elsner, P., John, SM., Maibach, H.I. (eds) Kanerva's Occupational Dermatology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-02035-3_123
Download citation
DOI: https://doi.org/10.1007/978-3-642-02035-3_123
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-02034-6
Online ISBN: 978-3-642-02035-3
eBook Packages: MedicineReference Module Medicine