Skip to main content

A Framework of the Non-invasive Ultrasound Theragnostic System

  • Conference paper

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5128))

Abstract

The authors have developed an Non-Invasive Ultrasound Theragnostic System to decrease the strain of patients and medical doctors. The system we propose tracks and follows movement in an affected area –kidney stones here– while High-Intensity Focused Ultrasound (HIFU) is irradiated onto the area. In this paper, a framework of the non-invasive ultrasound theragnostic system is proposed and illustrated. Specifically, the concept of the system is proposed at first. Secondly, decomposing and reconstructing (structuring) of the functional requirements are discussed. Third, the constructed system, which is based on those structured functional requirements, is illustrated. Fourth, the result of the servoing experiments of the model stone is reported to confirm the effectiveness of the proposed construction methodology and constructed system.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Kennedy, J.E., Ter Harr, G.R., Cranston, D.: High-intensity focused ultrasound: surgery of the future? The British Journal of Radiology 76, 590–599 (2003)

    Article  Google Scholar 

  2. Lynn, J.G., Zwemer, R.L., Chick, A.J., Miller, A.E.: A new method for the generation and use of focused ultrasound in experimental biology. J. Gen. Physiol. 26, 179–193 (1942)

    Article  Google Scholar 

  3. Ikeda, T., Yoshizawa, S., Tosaki, M., Allen, J.S., Takagi, S., Ohta, N., Kitamura, T., Matsumoto, Y.: Cloud Cavitation Control for Lithotripsy Using High Intensity Focused Ultrasound. Ultrasound Med. Biol. 32(9), 1383–1397 (2006)

    Article  Google Scholar 

  4. Wu, F., Wang, Z.L., Zhang, Z., et al.: Acute biological effects of high-intensity focused ultrasound on H22 liver tumours in vivo. Chin. Ultrasound Med. J. 13(3), 1–4 (1997)

    MATH  Google Scholar 

  5. Tu, G., Qiao, T.Y., He, S.: An experimental study on highintensity focused ultrasound in the treatment of VX-2 rabbit kidney tumours. Chin. Ultrasound Med. J. 20(8), 456–458 (1999)

    Google Scholar 

  6. Wu, F., Chen, W.Z., Bai, J., Zou, J.Z., Wang, Z.L., Zhu, H., Wang, Z.B.: Pathological changes in malignant carcinoma treated with high-intensity focused ultrasound. Ultrasound Med. Biol. 27(8), 1099–1106 (2001)

    Article  Google Scholar 

  7. Kennedy, J.E., Wub, F., ter Haarc, G.R., Gleesond, F.V., Phillipsd, R.R., Middletone, M.R., Cranstona, D.: Highintensity focused ultrasound for the treatment of liver tumours. Ultrasonics 41, 931–935 (2004)

    Article  Google Scholar 

  8. Pernot, M., et al.: 3-D Real-Time Motion Correction in High-Intensity Focused Ultrasound Therapy. Ultrasound Med. & Biol. 30(9), 1239–1249 (2004)

    Article  Google Scholar 

  9. Nakamura, Y., Kishi, H., Kawakami, H.: Robotic Stabilization that Assists Cardiac Surgery on Beating Hearts. In: Proc. of Medicine Meets Virtual Reality 2001, pp. 355–361 (2001)

    Google Scholar 

  10. Nakamura, Y., Kishi, H., Kawakami, H.: Heartbeat Synchronization for Robotic Cardiac Surgery. In: Proc. 2001 Int. Conf. Robotics and Automation, pp. 2014–2019 (2001)

    Google Scholar 

  11. Thankral, A., Wallace, J., Tomlin, D., Seth, N., Thakor, N.V.: Beating heart tracking in robotic surgery using 500 Hz visual servoing, model predictive control and an adaptice observer. In: Proc. 2004 Int. Conf. Robotics and Automation, vol. 1, pp. 274–279 (2004)

    Google Scholar 

  12. Ginhoux, R., Gangloff, J.A., Mathelin, M.F., Soler, L., Sanchez, M.A., Marescaux, J.: Beating heart tracking in robotic surgery using 500 Hz visual servoing, model predictive control and an adaptice observer. In: Proc. 2004 Int. Conf. Robotics and Automation, vol. 1, pp. 274–279 (2004)

    Google Scholar 

  13. McAteer, J.A., Williams, J.C., Evan, A.P., Cleveland, R.O., Cauwelaert, J.V., Bailey, M.R., Lifshitz, D.A.: The impact of the geometry of the lithotripter aperture on fragmentation effect at extracorporeal shock wave lithotripsy treatment. In: Urol. Res., vol. 33, pp. 429–434 (2004)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Takeyoshi Dohi Ichiro Sakuma Hongen Liao

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Koizumi, N. et al. (2008). A Framework of the Non-invasive Ultrasound Theragnostic System. In: Dohi, T., Sakuma, I., Liao, H. (eds) Medical Imaging and Augmented Reality. MIAR 2008. Lecture Notes in Computer Science, vol 5128. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-79982-5_26

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-79982-5_26

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-79981-8

  • Online ISBN: 978-3-540-79982-5

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics