Abstract
Electrocutions and collisions of birds with power lines have long represented an important worldwide conservation issue. Raptors such as eagles are susceptible to electrocution on distribution power lines because they are large birds and because certain species frequently perch or nest on power poles. Electrocution is an important cause of population declines among a number of sensitive raptor species. Electrocution risk is distributed unevenly among poles; for any pole, electrocution risk is a function of pole hazard (spacing between energized and grounded components) and exposure (pole utilization) by susceptible species. Habitat, sex, age, weather, and behavioral factors also play an important role in electrocution. Electrocution risk can be successfully mitigated by increasing separation between hazardous contacts, adding insulation, or attempting to redirect birds to safer locations. Statistical models are useful for identifying high risk poles, where mitigation can provide maximum conservation benefit. Raptor collisions with power lines also have been documented globally, and may involve sensitive species. Raptor collision risk appears to be elevated where lines bisect travel corridors, particularly when individuals are distracted by courtship, territorial defense, or hunting, or visibility is reduced by weather or low light. Collision can be reduced using devices increasing line visibility. Although numerous methods for reducing or eliminating electrocutions and collisions have been developed, published, and successfully implemented, raptor electrocutions and collisions persist. This chapter addresses common problems and solutions associated with raptor electrocutions and collisions.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Amezian M, Irizi A, Errati A, Loran H, El Khamlichi R, Morandini V, González DG, Garrido JR (2015) Spanish imperial eagles and other eagles found electrocuted in Morocco and proposition of correction measures. Available via figshare. https://doi.org/10.6084/m9.figshare.1613292. Accessed 12 Dec 2016
Angelov I, Hashim I, Oppel S (2013) Persistent electrocution mortality of Egyptian vultures Neophron percnopterus over 28 years in East Africa. Bird Conserv Int 23:1–6. https://doi.org/10.1017/S0959270912000123
Antal M (2010) Policy measures to address bird interactions with power lines – a comparative case study of four countries. Ostrich 81:217–223
Avian Power Line Interaction Committee (APLIC) (1994) Mitigating bird collisions with power lines: the state of the art in 1994. Edison Electric Institute, Washington, DC
Avian Power Line Interaction Committee (APLIC) (1996) Suggested practices for raptor protection on power lines: the state of the art in 1996. Edison Electric Institute/Raptor Research Foundation, Washington, DC
Avian Power Line Interaction Committee (APLIC) (2006) Suggested practices for avian protection on power lines: the state of the art in 2006. Edison Electric Institute, APLIC, and the California Energy Commission, Washington, DC/Sacramento
Avian Power Line Interaction Committee (APLIC) (2012) Reducing avian collisions with power lines: the state of the art in 2012. Edison Electric Institute and APLIC, Washington, DC
Avian Power Line Interaction Committee and U.S (2005) Fish and Wildlife Service (APLIC and USFWS) Avian protection plan (APP) guidelines
Barbazyuk EV, Bakka SV, Barashkova AN, Semenov AR, Smelyanskiy IE (2010) The outcomes of preliminary monitoring for death of raptors and other bird species through electrocution in the eastern Orenburg District, Russia. Raptors Conserv 20:40–47
Barrientos R, Alonso JC, Ponce C, Palacín C (2011) Meta-analysis of the effectiveness of marked wire in reducing avian collisions with power lines. Conservation. Biol 25(5):893–903
Bayle P (1999) Preventing birds of prey problems at transmission lines in western Europe. J Raptor Res 33:43–48
Beaulaurier DL (1981) Mitigation of bird collisions with transmission lines. Bonneville Power Administration, Portland
Benson PC (1980) Large raptor electrocution and power pole utilization: a study in six western states. Raptor Res 14:125–126
Benson, PC (1981) Large raptor electrocution and power line utilization: a study in six western states. PhD dissertation, Brigham Young University
BirdLife International (2017) International union for conservation of nature and natural resources red list for birds. http://www.birdlife.org. Accessed 18 Jan 2017
Blackwell BF, DeVault TL, Seamans TW, Lima SL, Baumhardt P, Fernández-Juricic E (2012) Exploiting avian vision with aircraft lighting to reduce bird strikes. J Appl Ecol 49(4):758–766
Boeker EL, Nickerson PR (1975) Raptor electrocutions. Wildl Soc Bull 3(2):79–81
Boshoff AF, Minne JC, Tambling CJ, Michael MD (2011) The impact of power line-related mortality on the cape vulture (Gyps coprotheres) in a part of its range, with an emphasis on electrocution. Bird Conserv Int 21:311–327
Brown WM, Drewien RC (1995) Evaluation of two power line markers to reduce crane and waterfowl mortality. Wildl Soc Bull 23:217–227
Burnham JT (1995) Bird streamer flashovers on FPL transmission lines. IEEE Trans Power Delivery 10:970–977
Cartron J-LE, Harness RE, Rogers RC, Manzano-Fischer P (2005) Impact of concrete power poles on raptors and ravens in northwestern Chihuahua, Mexico. In: Cartron J-L, Ceballos G, Felger RS (eds) Biodiversity, ecosystems, and conservation in northern Mexico. Oxford University Press, New York, pp 357–369
Coues E (1876) The destruction of birds by telegraph wires. Am Nat 10:734–736
Demerdzhiev DA (2014) Factors influencing bird mortality caused by power lines within special protected areas and undertaken conservation efforts. Acta Zool Bulg 66(2):411–423
Demerdzhiev DA, Stoychev SA, Petrov TH, Angelov ID, Nedyalkov NP (2009) Impact of power lines on bird mortality in southern Bulgaria. Acta Zool Bulg 61(2):175–183
Dickerman RW (2003) Talon-locking in the red-tailed hawk. J Raptor Res 37:176
Dixon A, Maming R, Gungaa A, Purev-Ochir G, Batbayar N (2013) The problem of raptor electrocution in Asia: case studies from Mongolia and China. Bird Conserv Int 23:520–529. https://doi.org/10.1017/S0959270913000300
Donázar JA, Palacios CJ, Gangoso L, Ceballos O, González MJ, Hiraldo F (2002) Conservation status and limiting factors in the endangered population of Egyptian vulture (Neophron percnopterus) in the Canary Islands. Biol Conserv 107:89–97
Dwyer JF (2004) Investigating and mitigating raptor electrocution in an urban environment. MS Thesis, University of Arizona, Tucson
Dwyer JF (2006) Electric shock injuries in a Harris’s hawk population. J Raptor Res 40(3):193–199
Dwyer JF (2009) Raptor electrocution: a case study on ecological traps, sinks, and additive mortality. J Nat Resour Life Sci Educ 38:93–98. https://doi.org/10.4195/jnrlse.2009.0002u
Dwyer JF, Doloughan K (2014) Testing systems of avian perch deterrents on electric power distribution poles. Hum-Wildl Interact 7:39–54
Dwyer JF, Mannan RW (2007) Preventing raptor electrocutions in an urban environment. J Raptor Res 41:59–267
Dwyer JF, Harness RE, Donohue K (2013) Predictive model of avian electrocution risk on overhead power lines. Conserv Biol 28(1):159–168. https://doi.org/10.1111/cobi.12145
Dwyer JF, Kratz GE, Harness RE, Little SS (2015) Critical dimensions of raptors on electric utility poles. J Raptor Res 49(2):210–216
Dwyer JF, Harness RE, Gerber BD, Landon MA, Petersen P, Austin DD, Woodbridge B, Williams GE, Eccleston D (2016a) Power pole density informs spatial prioritization for mitigating avian electrocution. J Wildl Manag 80:634–642. https://doi.org/10.1002/jwmg.1048
Dwyer JF et al (2016b) Avian electrocutions on incorrectly retrofitted power poles. Final report submitted to the USFWS, Western Golden Eagle Conservation Team (in press)
Electric Power Research Institute (EPRI) (1982) Prevention of golden eagle electrocution. EPRI EA-2680. Palo Alto
Electric Power Research Institute (EPRI) (2013) Effectiveness and durability of animal-caused outage prevention products. EPRI 3002001185, Palo Alto
Electric Power Research Institute (EPRI) (2014) Animal bushing cover testing: current practices and opportunities to improve comparability and transparency. EPRI 3002003574, Palo Alto
Electric Power Research Institute (EPRI) (2016) Conductor cover selection: an animal outage device selection process to maximize installation ease, system compatibility, and overall performance. EPRI 3002006333, Palo Alto
Ellis DH, Craig T, Craig E, Postupalsky S, Larue CT, Nelson RW, Henny CJ, Watson J, Millsap BA, Dawson JW, Cole KL, Martin EM, Margalida A, Kung P (2009) Unusual raptor nests around the world. J Raptor Res 43:175–198
Fernández-Juricic E, Gaffney J, Blackwell BF, Baumhardt P (2011) Bird strikes and aircraft fuselage color: a correlational study. Hum-Wildl Interact 5(2):224–234
Ferrer M, Hiraldo F (1992) Man-induced sex-biased mortality in Spanish imperial eagles. Biol Conserv 60:57–60
Ferrer M, De La Riva M, Castroviejo J (1991) Electrocution of raptors on power lines in southwestern Spain. J Field Ornithol 62:181–190
Fox N, Wynne C (2010) The impact of electrocution on the New Zealand falcon (Falco novaeseelandiae). Notornis 57:71–74
Galmes MA, Sarasola JH, Grande JM, Vargas FH (in press) Electrocution risk for the endangered crowned solitary eagle and other birds in semiarid landscapes of central Argentina. Bird Conserv International. https://doi.org/10.1017/S0959270917000272
Garrett MG (1993) PacifiCorp’s program for managing birds on power lines- a case study. In: Huckabee JW (ed) Proceedings of the avian interactions with utility structures international workshop, Miami, September 1992, p 18–1–18-5
Gerdzhikov GP, Demerdzhiev DA (2009) Data on bird mortality in “Sakar” IBA (BG021), caused by hazardous power lines. Ecol Balk 1:67–77
González LM, Margalida A, Mañosa S, Sánchez R, Oria J, Molina JI, Caldera J, Aranda A, Prada L (2007) Causes and spatio-temporal variations of non-natural mortality in the vulnerable Spanish imperial eagle Aquila adalberti during a recovery period. Oryx 41(4):495–502. https://doi.org/10.1017/S0030605307414119
Goroshko OA (2011) Bird electrocution in the Daurian steppe (south-eastern trans-Baikal region), Russia. Raptors Conserv 21:84–99
Guil F, Fernández-Olalla M, Moreno-Opo R, Mosqueda I, Gómez ME, Aranda A, Arrendondo Á, Guzmán J, Oria J, González LM, Margalida A (2011) Minimising mortality in endangered raptors due to power lines: the importance of spatial aggregation to optimize the application of mitigation measures. PLoS One 6(11):e28212
Guil F, Colomer MA, Moreno-Opo R, Margalida A (2015) Space-time trends in Spanish bird electrocution rates from alternative information sources. Glob Ecol Conserv 3:379–388
Guyonne FE, Ferrer J, Ferrer M (1999) Mitigation of raptor electrocution on steel power poles. Wildl Soc Bull 27(2):263–273
Guzmán J, Castaño JP (1998) Electrocucion de rapaces en lineas electricas de distribucion en Sierra Morena Oriental y Campo de Montiel. Ardeola 45(2):161–169
Hall KL (2012) Out of sight, out of mind: an updated study on the undergrounding of overhead power lines. Edison Electric Institute, Washington, DC
Hallinan T (1922) Bird interference on high tension electric transmission lines. Auk 39:573
Hamerstrom FN Jr, Harrell BE, Olendorff RR (eds) (1974) Management of raptors – proceedings of the conference on raptor conservation techniques, Fort Collins, March 1973. Part 4. Raptor Res Foundation, Inc, Raptor Res Rpt no 2
Harness RE (2000a) Steel distribution poles – environmental implications. In: Chancellor RD, Meyburg B-U (eds) Raptors at risk. Hancock House, Blaine, pp 751–755
Harness RE (2000b) Raptor electrocutions and distribution pole types. North American Wood Pole Council Technical Bulletin-Raptor-10-00
Harness RE (2001) Effectively retrofitting power lines to reduce raptor mortality. In: The leading edge: meeting environmental challenges for siting and reliability, 44th annual IEEE Rural Electric Power Conference, Louisville, 7–9 May 2000
Harness RE (2004) Bald Eagle Haliaeetus leucocephalus electrocutions in Alaska and Florida – a comparison of retrofitting measures. In: Chancellor RD, Meyburg B-U (eds) Raptors worldwide. Proceedings of the 6th world conference on birds of prey and owls, Budapest, 2003
Harness RE (2007) Mitigation. In: Bird DM, Bildstein KL (eds) Raptor research and management techniques. Hancock House, Surrey/British Columbia, pp 365–382
Harness RE, Juvvadi PR (2013) Bird electrocutions in Western Rajasthan, India. 2013 Proceedings of the IEE Rural Electric Power Conference, Stone Mountain, Georgia, April–May 2013, p A4–1 to A4–5
Harness RE, Kratz G (2007) Bird streamers as the probable cause of a bald eagle electrocution. Colo Birds 41(2):86–90
Harness RE, Wilson KR (2001) Utility structures associated with raptor electrocutions in rural areas. Wildl Soc Bull 29:612–623
Harness RE, Milodragovich S, Schomburg J (2003) Raptors and power line collisions. Colo Birds 37(3):118–122
Harness RE, Gombobaatar S, Yosef R (2008) Mongolian distribution power lines and raptor electrocutions. Papers presented at the 52nd annual conference, Charleston, 27–30 April 2008
Harness RE, Juvvadi PR, Dwyer JF (2013) Avian electrocutions in western Rajasthan, India. J Raptor Res 47:352–364
Håstad O, Ödeen A (2014) A vision physiological estimation of ultraviolet window marking visibility to birds. PeerJ. https://doi.org/10.7717/peerj.621
Heck N, Sutherland T (2013) Use of custom-fitted cover-ups to reduce power outages and mitigate avian electrocutions. T&D Magazine Nov-Dec p 21–25
Hernández-Matías A, Real J, Parés F, Pradel R (2015) Electrocution threatens the viability of populations of the endangered Bonelli’s eagle (Aquila fasciata) in southern Europe. Biol Conserv 191:110–116
Hunting K (2002) A roadmap for PIER research on avian collisions with power lines in California. Technical report P500–02-071F. California Energy Commission, Sacramento
Hurst N (2004) Corona testing devices used to mitigate bird collisions. EDM International, California Energy Commission, PIER Energy-Related Environmental Research. #500 04 086F
Ibarra J, De Lucca E (2015) Águilas Moras (Geranoaetus melanoleucus), víctimas de electrocución en luján de cuyo, Mendoza, Argentina. Nótulas Faunísticas 176 Segunda Serie 176:1–7
Institute of Electrical and Electronics Engineers (IEEE) (2010) Guide for testing the electrical, mechanical, and durability performance of wildlife protective devices on overhead power distribution systems rated up to 38kV. New York
Janss GFE (2000) Avian mortality from power lines: a morphologic approach of a species-specific mortality. Biol Conserv 95(3):353–359
Janss GFE, Ferrer M (1999a) Avian electrocution on power poles: European experiences. In: Ferrer M, Janss GFE (eds) Birds and power lines: collision, electrocution, and breeding. Quercus Editores, Madrid, pp 145–164
Janss GFE, Ferrer M (1999b) Mitigation of raptor electrocution on steel power poles. Wildl Soc Bull 27:263–273
Jenkins AR, de Goede KH, Sebele L, Diamond M (2013) Brokering a settlement between eagles and industry: sustainable management of large raptors nesting on power infrastructure. Bird Conserv Int 23:232–246. https://doi.org/10.1017/S0959270913000208
Johnson B (2004) Out of sight, out of mind? A study on the costs and benefits of undergrounding overhead power lines. Edison Electric Institute, Washington, DC
Kagan RA (2016) Electrocution of raptors on power lines: a review of necropsy methods and findings. Vet Pathol 53(5):1030–1036. https://doi.org/10.1177/0300985816646431
Kemper CM, Court GS, Black JA (2013) Estimating raptor electrocution mortality on distribution power lines in Alberta, Canada. J Wildl Manag 77:1342–1352
Lasch U, Zerbe S, Lenk M (2010) Electrocution of raptors at power lines in Central Kazakhstan. Waldökologie, Landschaftsforschung und Naturschutz 9:95–100
Ledger JA (1984) Engineering solutions to the problem of vulture electrocutions on electricity towers. Certif Eng 57:92–95
Ledger JA, Hobbs JCA (1999) Raptor use and abuse of powerlines in southern Africa. J Raptor Res 33(1):49–52
Lehman RN (2001) Raptor electrocution on power lines: current issues and outlook. Wildl Soc Bull 29:804–813
Lehman RN, Barrett JS (2002) Raptor electrocutions and associated fire hazards in the Snake River Birds of Prey National Conservation Area. Technical bulletin No. 02–7, Idaho Bureau of Land Management, Boise
Lehman RN, Kennedy PL, Savidge JA (2007) The state of the art in raptor electrocution research: a global review. Biol Conserv 136:159–178
Lehman RN, Kennedy PL, Savidge JA, Harness RE (2010) Raptor electrocution rates for a utility in the intermountain western United States. J Wildl Manag 74(3):459–470. https://doi.org/10.2193/2008-332
Lobermeier S, Moldenhauer M, Peter CM, Slominski L, Tedesco RA, Meer MV, Dwyer JF, Harness RE, Stewart AH (2015) Mitigating avian collision with power lines: a proof of concept for installation of line markers via unmanned aerial vehicle. J Unmanned Veh Syst 3(4):252–258
López-López P, Ferrer M, Madero A, Casado E, McGrady M (2011) Solving man-induced large-scale conservation problems: the Spanish imperial eagle and power lines. PLoS One. https://doi.org/10.1371/0017196
Loss SR, Will T, Marra PP (2014) Refining estimates of bird collision and electrocution mortality at power lines in the United States. PLoS One. https://doi.org/10.1371/0101565
Luzenski J, Rocca CE, Harness RE, Cummings JL, Austin DD, Landon MA, Dwyer JF (2016) Collision avoidance by migrating raptors encountering a new transmission power line. Condor 118(2):402–410
Mañosa S, Real J (2001) Potential negative effects of collisions with transmission lines on a Bonelli’s eagle population. J Raptor Res 35(3):247–252
Manville AM II (2005) Birds strikes and electrocutions at power lines, communications towers, and wind turbines: state of the art and state of the science—next steps toward mitigation. U.S. Forest Service General Technical Report PSW-GTR-191, Washington, DC
Matsyna AI, Matsyna EL, Matsyna AA, Grishutkin GF, Spiridonov SN (2010) Estimating the efficiency of bird protection activities on power lines 6-10 kV in the national park of Smolny, Russia. Raptors Conserv 20:35–39
Melcher C, Suazo LR (1999) Raptor electrocutions: the unnecessary losses continue. J of the Colo Field Ornithol 33:221–224
Meretsky VJ, Snyder NFR, Beissinger SR, Clendenen DA, Wiley JW (2001) Demography of the California condor: implications for reestablishment. Conserv Biol 14:957–967
Mojica EK, Watts BD, Paul JT, Voss ST, Pottie J (2009) Factors contributing to bald eagle electrocutions and line collisions on Aberdeen proving ground, Maryland. J Raptor Res 43:57–61
Morkill AE (1990) Effectiveness of markers in reducing Sandhill Crane collisions with power lines. MS Thesis, University of Wyoming, Laramie
Morkill AE, Anderson SH (1991) Effectiveness of marking powerlines to reduce Sandhill crane collisions. Wildl Soc Bull 19:442–449
Murphy RK, Mojica EK, Dwyer JF, McPherron MM, Wright GD, Harness RE, Pandey AK, Serbousek KL (2016) Crippling and nocturnal biases in as study of Sandhill crane (Grus canadensis) collisions with a transmission line. Waterbirds 39:312–317
Nelson MW (1979) Power lines progress report on eagle protection research. Idaho Power Company, Boise
Nelson MW (1980) Update on eagle protection practices. Idaho Power Company, Boise
Nelson MW, Nelson P (1976) Power lines and birds of prey. Idaho Wildl Rev 28:3–7
Nelson MW, Nelson P (1977) Power lines and birds of prey. In: Chandler RD (ed) Proceedings of world conference on birds of prey, International Council for Bird Preservation, Vienna, 1975
Newton I (2010) Population ecology of raptors. Poyser, London
O’Neil T (1988) An analysis of bird electrocutions in Montana. J Raptor Res 22:27–28
Olendorff RR (1972) Eagles, sheep and power lines. Colo Outdoors 21(1):3–11
Olendorff RR, Lehman RN (1986) Raptor collisions with utility lines: an analysis using subjective field observations. Final report. Pacific Gas and Electric Co., Research and Development, San Ramon
Olendorff RR, Miller AD, Lehman RN (1981) Suggested practices for raptor protection on power lines: the state of the art in 1981. Raptor Research Report No. 4. Raptor Research Foundation, University of Minnesota, St. Paul
Phipps WL, Wolter K, Michael MD, MacTavish LM, Yarnell RW, Farwig N (2013) Do Power Lines and Protected Areas Present a Catch-22 Situation for Cape Vultures (Gyps coprotheres)?. PLoS ONE 8 (10):e76794
Platt C (2005) Patterns of raptor electrocution mortality on distribution power lines in southeast Alberta. MS Thesis, University of Alberta
Pope VR, Fielder PC, Cordell KA, Harness RE, Hamer TE (2006) Pre-construction evaluation of collision potential for fall migrating raptors with a transmission line across Burch Mountain, Chelan County, Washington. Public Utility District No. 1 of Chelan County, EDM International, and Hamer Environmental, Wenatchee, Fort Collins, Mount Vernon
Prather PR, Messmer TA (2010) Raptor and corvid response to power distribution line perch deterrents in Utah. J Wildl Manag 74(4):796–800. https://doi.org/10.2193/2009-204
Prinsen H, Boere G, Píres N, Smallie J (2011) Review of the conflict between migratory birds and electricity power grids in the African-Eurasian region. Tenth meeting of the conference of the parties Bergen, 20–25 November 2011
Reynolds B, Dupre R, Eccleston D, “To protect and deter,” T&D World Magazine. [Online]. Sept 2014, pp. 54-58. Available: http://tdworld.com/overhead-transmission/protect-and-deter.
Rioux S, Savard J-PL, Gerick AA (2013) Avian mortalities due to transmission line collisions: a review of current estimates and field methods with an emphasis on applications to the Canadian electric network. Avian Conserv Ecol 8(2):7
Rollan A, Real J, Bosch R, Tintó A, Hernandez-Matias A (2010) Modeling the risk of collision with power lines in Bonelli’s eagle Hieraaetus fasciatus and its conservation implications. Bird Conserv Int 20:279–294
Schürenberg B, Schneider R, Jerrentrup H (2010) Implementation of recommendation no. 110/2004 on minimising adverse effects of above- ground electricity transmission facilities (power lines) on birds. Convention on the conservation of European wildlife and natural habitats. Strasbourg
Snyder NFR (2007) Limiting factors for wild California condors. In: Mee A, Hall LS (eds) California condors in the 21st century. Nuttall Ornithological Club and the American Ornithologists’ Union, Washington, DC, pp 9–33
Snyder N, Snyder H (2000) The California condor, a saga of natural history and conservation. Academic Press, London
Spencer R (2016) Ridgway’s Hawks in the Dominican Republic. Presentation at the international conference on overhead lines, Fort Collins, 4–7 April 2016
Sporer MK, Dwyer JF, Gerber BD, Harness RE, Pandey AK (2013) Marking power lines to reduce avian collisions near the Audubon National Wildlife Refuge, North Dakota. Wildl Soc Bull 37:796–804
Suazo LR (1998) Powerlines and raptors: using regulatory influence to prevent electrocutions. Paper presented at fifth world conference on birds of prey and owls. Midrand, South Africa
Switzer F (1977) Saskatchewan Power’s experience. Blue Jay 35:259–260
Tintó A, Real J, Mañosa S (2010) Predicting and correcting electrocution of birds in Mediterranean areas. J Wildl Manag 74:1852–1862
Van Rooyen C, Vosloo H, Harness RE (2002) Eliminating bird streamers as a cause of faulting on transmission lines. Proceedings of Rural Electric Power Conference, Colorado Springs
Van Rooyen C, Vosloo H, Harness RE (2003) Watch the birdie! IEEE Ind Appl Mag 9:55–60
Vanderburgh DC (1993) Manitoba hydro accommodates osprey. Blue Jay 51:173–177
Watts BD, Mojica EK, Paxton BJ (2015) Using Brownian bridges to assess potential interactions between bald eagles and electrical hazards within the upper Chesapeake Bay. J Wildl Manag 79:435–445
Zhou Y, Hu H, Xu X, Cui J, Yuan Y, Li Z, Chen Y, Yu D, Nie Q, Liang X, Guan Z (2009) High-risk region of bird streamer flashover in high-voltage transmission lines. J Electrost 67:311–315
Acknowledgments
We’d like to thank EDM International, Inc. for supporting the effort to develop this section. Special thanks to reviewers and co-workers Libby Mojica, Melissa Landon, and Dr. James Dwyer. Bryon Robb helped develop figure 2 and figure 8. We also wish to thank the Electric Power Research Institute, California Energy Commission, National Rural Electric Association, US Fish and Wildlife Service, and the Avian Power Line Interaction Committee for sponsoring ongoing research that contributed greatly to the development of this chapter.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG, part of Springer Nature
About this chapter
Cite this chapter
Eccleston, D.T., Harness, R.E. (2018). Raptor Electrocutions and Power Line Collisions. In: Sarasola, J., Grande, J., Negro, J. (eds) Birds of Prey. Springer, Cham. https://doi.org/10.1007/978-3-319-73745-4_12
Download citation
DOI: https://doi.org/10.1007/978-3-319-73745-4_12
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-73744-7
Online ISBN: 978-3-319-73745-4
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)