Evaluation and Management of Ventilator-Patient Dyssynchrony

  • Chapter
  • First Online:
Cardiopulmonary Monitoring

Abstract

Mechanical ventilation in critically ill patients has to effectively unload inspiratory muscles and provide a safe ventilation (enhancing gas exchange and protecting the lungs and the diaphragm). To do that, the ventilator should be in synchrony with patient’s respiratory rhythm. Dyssynchrony between the patient and the ventilator may induce several deleterious effects, and a proper physiological understanding is required in order to recognize and manage. Different tools have been developed and proposed besides the careful analysis of the ventilator waveforms that aim to help physicians in the decision-making strategy. Additionally, appropriate handling of asynchronies requires clinical skills, physiological knowledge, and suitable drug management. Moreover, new technologies and devices are currently changing our daily practice, going from automated real-time recognition of asynchronies and their distribution during mechanical ventilation to smart-alarm-personalized medicine. Our goal as clinicians relies in careful care of patients based on the more accurate and current knowledge, and incorporate new technological methods that aims to facilitate and improve the care of the critically ill.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 279.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Akoumianaki E, Lyazidi A, Rey N, Matamis D, Perez-Martinez N, Giraud R, et al. Mechanical ventilation-induced reverse-triggered breaths: a frequently unrecognized form of neuromechanical coupling. Chest. 2013;143(4):927–38.

    Article  Google Scholar 

  • Aquino Esperanza J, Sarlabous L, de Haro C, Magrans R, Lopez-Aguilar J, Blanch L. Monitoring asynchrony during invasive mechanical ventilation. Respir Care. 2020;65(6):847–69. https://doi.org/10.4187/respcare.07404.

  • Barr J, Fraser GL, Puntillo K, Ely EW, Gélinas C, Dasta JF, et al. Clinical practice guidelines for the management of pain, agitation, and delirium in adult patients in the intensive care unit: executive summary. Am J Heal Pharm. 2013;70(1):53–8.

    Article  Google Scholar 

  • Beitler JR, Sands SA, Loring SH, Owens RL, Malhotra A, Spragg RG, et al. Quantifying unintended exposure to high tidal volumes from breath stacking dyssynchrony in ARDS: the BREATHE criteria. Intensive Care Med. 2016;42(9):1427–36.

    Article  Google Scholar 

  • Blanch L, Sales B, Montanya J, Lucangelo U, Oscar GE, Villagra A, et al. Validation of the better care® system to detect ineffective efforts during expiration in mechanically ventilated patients: a pilot study. Intensive Care Med. 2012;38(5):772–80.

    Article  Google Scholar 

  • Blanch L, Villagra A, Sales B, Montanya J, Lucangelo U, Luján M, et al. Asynchronies during mechanical ventilation are associated with mortality. Intensive Care Med. 2015;41(4):633–41.

    Article  Google Scholar 

  • Brochard L, Slutsky A, Pesenti A. Mechanical ventilation to minimize progression of lung injury in acute respiratory failure. Am J Respir Crit Care Med. 2017;195:438–42.

    Article  Google Scholar 

  • Chanques G, Kress JP, Pohlman A, Patel S, Poston J, Jaber S, et al. Impact of ventilator adjustment and sedation-analgesia practices on severe asynchrony in patients ventilated in assist-control mode. Crit Care Med. 2013;41(9):2177–87.

    Article  Google Scholar 

  • de Haro C, López-Aguilar J, Magrans R, Montanya J, Fernández-Gonzalo S, Turon M, et al. Double cycling during mechanical ventilation: frequency, mechanisms, and physiological implications. Crit Care Med. 2018;46(9):1385–92.

    Article  Google Scholar 

  • de Haro C, Magrans R, López-aguilar J, Montanyà J, Lena E, Subirà C, et al. Effects of sedatives and opioids on trigger and cycling asynchronies throughout mechanical ventilation: an observational study in a large dataset from critically ill patients. Crit Care. 2019;23(1):245.

    Google Scholar 

  • de Vries HJ, Jonkman AH, Tuinman PR, Girbes ARJ, Heunks LMA. Respiratory entrainment and reverse triggering in a mechanically ventilated patient. Ann Am Thorac Soc. 2019;16(4):499–505.

    Article  Google Scholar 

  • de Wit M. Monitoring of patient-ventilator interaction at the bedside. Respir Care. 2011;56(1):61–72.

    Article  Google Scholar 

  • De Wit M, Miller KB, Green DA, Ostman HE, Gennings C, Epstein SK. Ineffective triggering predicts increased duration of mechanical ventilation. Crit Care Med. 2009;37(10):2740–5.

    PubMed  Google Scholar 

  • Delisle S, Charbonney E, Albert M. Patient–ventilator asynchrony due to reverse triggering occurring in brain-dead patients: clinical implications and physiological meaning. Am J Respir Crit Care Med. 2016;194(9):1166–8.

    Article  Google Scholar 

  • Fernandez R, Mendez M, Younes M. Effect of ventilator flow rate on respiratory timming in normal humans. Am J Respir Crit Care Med. 1999;159:710–9.

    Article  CAS  Google Scholar 

  • Flick GR, Bellamy PE, Simmons DH. Diaphragmatic contraction during assisted mechanical ventilation. Chest. 1989;96(1):130–5.

    Article  CAS  Google Scholar 

  • Gea J, Zhu E, Gáldiz JB, Comtois N, Salazkin I, Antonio Fiz J, et al. Functional consequences of eccentric contractions of the diaphragm. Arch Bronconeumol. 2009;45(2):68–74.

    Article  Google Scholar 

  • Georgopoulos D, Roussos C. Control of breathing in mechanically ventilated patients. Eur Respir J. 1996;9(10):2151–60.

    Article  CAS  Google Scholar 

  • Gilstrap D, Davies J. Patient-ventilator interactions. Clin Chest Med. 2016;37(4):669–81.

    Article  Google Scholar 

  • Gilstrap D, MacIntyre N. Patient-ventilator interactions implications for clinical management. Am J Respir Crit Care Med. 2013;188(9):1058–68.

    Article  Google Scholar 

  • Kallet RH, Alonso JA, Luce JM, Matthay MA. Exacerbation of acute pulmonary edema during assisted mechanical ventilation using a low-tidal volume, lung-protective ventilator strategy. Chest. 1999;116(6):1826–32.

    Article  CAS  Google Scholar 

  • Kallet RH, Campbell AR, Dicker RA, Katz JA, Mackersie RC. Effects of tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome. Crit Care Med. 2006;34(1):8–14.

    Article  Google Scholar 

  • Levine S, Nguyen T, Taylor N, Friscia M, Budak MT, Rothenberg P, et al. Rapid disuse atrophy of diaphragm fibers in mechanically ventilated humans. N Engl J Med. 2008;358(13):1327–35.

    Article  CAS  Google Scholar 

  • MacIntyre NR, McConnell R, Cheng K, Sane A. Patient-ventilator flow dyssynchrony: flow-limited versus pressure-limited breaths. Crit Care Med. 1997;25:161–7.

    Google Scholar 

  • Marini JJ, Rodriguez RM, Lamb V. The inspiratory workload of patient-initiated mechanical ventilation. Am Rev Respir Dis. 1986;134(5):902–9.

    Article  CAS  Google Scholar 

  • Murias G, Lucangelo U, Blanch L. Patient-ventilator asynchrony. Curr Opin Crit Care. 2016;22(1):53–9.

    Article  Google Scholar 

  • Pham T, Telias I, Piraino T, Yoshida T, Brochard LJ. Asynchrony consequences and management. Crit Care Clin. 2018;34(3):325–41.

    Article  Google Scholar 

  • Powers SK, Kavazis AN, Levine S. Prolonged mechanical ventilation alters diaphragmatic structure and function. Crit Care Med. 2009;37(Suppl. 10):347–53.

    Article  Google Scholar 

  • Rolland-Debord C, Bureau C, Poitou T, Belin L, Clavel M, Perbet S, et al. Prevalence and prognosis impact of patient – ventilator asynchrony in early phase of weaning according to two detection methods. Anesthesiology. 2017;127:989–97.

    Article  Google Scholar 

  • Subirà C, de Haro C, Magrans R, Fernández R, Blanch L. Minimizing asynchronies in mechanical ventilation: current and future trends. Respir Care. 2018;63(4):464–78.

    Article  Google Scholar 

  • Telias I, Brochard L, Goligher EC. Is my patient’s respiratory drive (too) high? Intensive Care Med. 2018;44(11):1936–9.

    Article  Google Scholar 

  • Thille AW, Rodriguez P, Cabello B, Lellouche F, Brochard L. Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Med. 2006;32(10):1515–22.

    Article  Google Scholar 

  • Vaporidi K, Babalis D, Chytas A, Lilitsis E, Kondili E, Amargianitakis V, et al. Clusters of ineffective efforts during mechanical ventilation: impact on outcome. Intensive Care Med. 2017;43(2):184–91.

    Article  Google Scholar 

  • Vaschetto R, Cammarota G, Colombo D, Longhini F, Grossi F, Giovanniello A, et al. Effects of propofol on patient-ventilator synchrony and interaction during pressure support ventilation and neurally adjusted ventilatory assist. Crit Care Med. 2014;42(1):74–82.

    Article  CAS  Google Scholar 

  • Yoshida T, Fujino Y, Amato MBP, Kavanagh BP. Fifty years of research in ARDS spontaneous breathing during mechanical ventilation risks, mechanisms, and management. Am J Respir Crit Care Med. 2017;195(8):985–92.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to José Aquino-Esperanza .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2021 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Lena, E., Aquino-Esperanza, J., Sarlabous, L., Lucangelo, U., Blanch, L. (2021). Evaluation and Management of Ventilator-Patient Dyssynchrony. In: Magder, S., Malhotra, A., Hibbert, K.A., Hardin, C.C. (eds) Cardiopulmonary Monitoring. Springer, Cham. https://doi.org/10.1007/978-3-030-73387-2_46

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-73387-2_46

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-73386-5

  • Online ISBN: 978-3-030-73387-2

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics