Abstract
Medical textile plays an important role in the technical textiles sector as one of the most rapidly growing sectors in the technical textile market. The textile materials should have some adequate mechanical properties to be useful as medical textile. Tensile strength presents one of the basic mechanical properties used to describe textile specimens. Standardized tensile testing procedures on textile specimens were commonly used in the past. The aim of this paper was to measure in-plane strain field on the tensile medical textile specimen using 2D Digital Image Correlation method (2D-DIC). 2D-DIC is a non-contact optical method for accurate displacement and strain full-field measurement. In this study, two medical cotton textiles, with density 120 and 130 g/m2, were used to create three specimens for each material. Each specimen was placed in the tensile testing machine and measured until the break. During the tensile testing, camera was automatically recording full-field displacement in X and Y directions. Textile 1 and Textile 2 showed significant differences in point distance values, despite the small deviation in densities (less than 10%). Mean value of the elongation for Textile 1 is more than a double than the elongation for Textile 2, although the difference for mean value of Maximum force if negligible. Also, it has been showed that 2D-DIC can play significant role for measurement in textile mechanical properties measurement.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Anand, S., Kennedy, J., Miraftab, M., Rajendran, S. (eds.): Medical and Healthcare Textiles. Woodhead Publishing Limited, Sawston (2010)
Asanovic, K., Cerovic, D., Mihailovic, T., Kostic, M., Reljic, M.: Quality of clothing fabrics in terms of their comfort properties Quality of clothing fabrics in terms of their comfort properties. Indian J. Fibre Text. Res. 40, 363–372 (2015)
Barbulov-Popov, D., Cirkovic, N., Stepanovic, J., Reljić, M.: The analysis of the parameters that influence the seam strength. Ind. Textil. 63, 131–136 (2012)
Reljic, M., Stojiljkovic, S., Stepanovic, J., Lazic, B., Stojiljkovic, M.: Study of water vapor resistance of Co/PES fabrics properties during maintenance. In: Mitrovic, N., Milosevic, M., Mladenovic, G. (eds.) Experimental and Numerical Investigations in Materials Science and Engineering, pp. 72–83. Springer, Cham (2019)
Stepanovic, J., Cirkovic, N., Radivojevic, D., Reljic, M.: Defining the warp length required for weaving process. Ind. Textil. 63, 227–231 (2012)
Wilusz, E. (ed.): Military Textiles. Woodhead Publishing Limited, Sawston (2008)
Hursa, A., Rolich, T., Ercegovic Razic, S.: Determining pseudo Poisson’s ratio of woven fabric with a digital image correlation method. Text. Res. J. 79, 1588–1598 (2009)
Meskuotiene, A., Dargiene, J., Domskiene, J.: Metrological performance of the digital image analysis method applied for investigation of textile deformation. Text. Res. J. 85, 71–79 (2015)
Wijeratne, R.S., De Vita, R., Rittenhouse, J.A., Orler, E.B., Moore, R.B., Dillard, D.A.: Biaxial properties of individual bonds in thermomechanically bonded nonwoven fabrics. Text. Res. J. 89, 698–710 (2019)
Sutton, M.A., Orteu, J.-J., Schreier, H.: Image Correlation for Shape, Motion and Deformation Measurements: Basic Concepts. Theory and Applications. Springer, Boston (2009)
Mitrovic, N., Petrovic, A., Milosevic, M., Momcilovic, N., Miskovic, Z., Maneski, T., Popovic, P.: Experimental and numerical study of globe valve housing. Hem. Ind. 71, 251–257 (2017)
Mitrovic, A., Mitrovic, N., Tanasic, I., Miloševic, M., Antonovic, D.: Measurement of strain field in glass ionomer cement. Struct. Integr. Life. 19, 143–147 (2019)
Kovačević, T., Rusmirović, J., Tomić, N., Mladenović, G., Milošević, M., Mitrović, N., Marinković, A.: Effects of oxidized/treated non-metallic fillers obtained from waste printed circuit boards on mechanical properties and shrinkage of unsaturated polyester-based composites. Polym. Compos. 40, 1170–1186 (2019)
Manojlovic, D., Dramićanin, M.D., Milosevic, M., Zeković, I., Cvijović-Alagić, I., Mitrovic, N., Miletic, V.: Effects of a low-shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on curing efficiency and mechanical properties of experimental resin-based composites. Mater. Sci. Eng. C 58, 487–494 (2016)
Miletic, V., Manojlovic, D., Milosevic, M., Mitrovic, N., Stankovic, T., Maneski, T.: Analysis of local shrinkage patterns of self-adhering and flowable composites using 3D digital image correlation. Quintessence Int. (Berl) 42, 797–804 (2011)
Miletic, V., Peric, D., Milosevic, M., Manojlovic, D., Mitrovic, N.: Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites. Dent. Mater. 32, 1441–1451 (2016)
Mitrovic, A., Mitrovic, N., Maslarevic, A., Adzic, V., Popovic, D., Milosevic, M., Antonovic, D.: Thermal and mechanical characteristics of dual cure self-etching, self-adhesive resin based cement. In: Lecture Notes in Networks and Systems, pp. 3–15. Springer, Cham (2019)
Lezaja, M., Veljovic, D., Manojlovic, D., Milosevic, M., Mitrovic, N., Janackovic, D., Miletic, V.: Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization. Dent. Mater. 31, 171–181 (2015)
Mitrović, A., Antonović, D., Tanasić, I., Mitrović, N., Bakić, G., Popović, D., Milošević, M.: 3D digital image correlation analysis of the shrinkage strain in four dual cure composite cements. Biomed. Res. Int. 2019, 7 (2019)
Tanasić, I., Mitrović, A., Mitrović, N., Šarac, D., Tihaček-šojić, L., Milić-Lemić, A., Milošević, M.: Analyzing strain in samples with all-ceramic systems using the digital image correlation technique. Srp. Arh. Celok. Lek. 2019, 528–533 (2019)
Tihacek-Sojic, L., Milic Lemic, A., Tanasic, I., Mitrovic, N., Milosevic, M., Petrovic, A.: Compressive strains and displacement in a partially dentate lower jaw rehabilitated with two different treatment modalities. Gerodontology 29, 851–857 (2012)
Tanasic, I., Milic-Lemic, A., Tihacek-Sojic, L., Stancic, I., Mitrovic, N.: Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method. Biomech. Model. Mechanobiol. 11, 751–758 (2012)
Šarac, D., Atanasovska, I., Vulović, S., Mitrović, N., Tanasić, I.: Numerical study of the effect of dental implant inclination. J. Serbian Soc. Comput. Mech. 11, 63–79 (2017)
Sarac, D., Mitrovic, N., Tanasic, I., Miskovic, Z., Tihacek-Sojic, L.: Experimental analysis of dental-implant load transfer in polymethyl-methacrylate blocks. Mater. Tehnol. 53, 133–137 (2019)
Tanasić, I., Šarac, D., Mitrović, N., Tihaček-Šojić, L., Mišković, Ž., Milić-Lemić, A., Milošević, M.: Digital image correlation analysis of vertically loaded cylindrical Ti-implants with straight and angled abutments. Exp. Tech. 40(4), 1227–1233 (2016)
Šarac, D., Mitrović, N.R., Tanasić, I.V., Tihaček-Šojić, L.: Experimental methodology for analysis of influence of dental implant design on load transfer. FME Trans. 46, 266–271 (2018)
Milošević, M., Milošević, N., Sedmak, S., Tatić, U., Mitrović, N., Hloch, S., Jovičić, R.: Digital image correlation in analysis of stiffness in local zones of welded joints. Teh. Vjesn. Tech. Gaz. 23, 19–24 (2016)
Sedmak, A., Milošević, M., Mitrović, N., Petrović, A., Maneski, T.: Digital image correlation in experimental mechanical analysis. Struct. Integr. Life. 12, 39–42 (2012)
EN ISO 13934: Textiles—Tensile properties of fabrics—Part 1: Determination of maximum force and elongation at maximum force using the strip method
Acknowledgement
This research was supported by Ministry of Education, Science and Technological Development of Republic of Serbia under Project TR35031.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Mitrovic, N., Mitrovic, A., Reljic, M. (2021). Strain Measurement of Medical Textile Using 2D Digital Image Correlation Method. In: Mitrovic, N., Mladenovic, G., Mitrovic, A. (eds) Experimental and Computational Investigations in Engineering. CNNTech 2020. Lecture Notes in Networks and Systems, vol 153. Springer, Cham. https://doi.org/10.1007/978-3-030-58362-0_26
Download citation
DOI: https://doi.org/10.1007/978-3-030-58362-0_26
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-58361-3
Online ISBN: 978-3-030-58362-0
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)