Abstract
The paper presents the results of finite element analysis (Ansys) of personalized bone fixation plates for LeFort I osteotomy. Personalized bone fixation plates were designed on the maxilla model with local individual material properties, obtained from CT scans. Maxilla model with osteotomy was loaded with three load cases of bite forces with a value of 200 N were analyzed and then a static analysis was carried out for each situation. The results showed that titanium plates withstand the set stresses and there is no damage to bones and stabilization plates.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Basiaga, M., Staszuk, M., Walke, W., Tański, T., Kajzer, W.: Potentiostatic, potentiodynamic and impedance study of TiO\(_{2}\) layers deposited of 316 LVM steel used for coronary stents. Arch. Metall. Mater. 61(2), 821–824 (2016)
Basiaga, M., Jendruś, R., Walke, W., Paszenda, Z., Kaczmarek, M., Popczyk, M.: Influence of surface modification on properties of stainless steel used for implants. Arch. Metall. Mater. 60(4), 2965–2969 (2015)
Basiaga, M., Staszuk, M., Walke, W., Opilski, Z.: Mechanical properties of atomic layer deposition TiO\(_{2}\) layers on stainless steel substrate. Materialwissenschaft und Werkstofftechnik 47(5), 522–520 (2016)
Borie, E., Orsi, I.A., Fuentes, R., Beltrán, V., Navarro, P., Pareja, F., Raimundo, L.B.: Maximum bite force in elderly indigenous and non-indigenous denture wearers. Acta Odontol. Latinoam. 27(3), 115–119 (2014)
Chiapasco, M., Romeo, E., Coggiola, A., Brusati, R.: Long-term outcome of dental implants placed in revascularized fibula free flaps used for the reconstruction of maxillo-mandibular defects due to extreme atrophy. Clin. Oral Implant. Res. 22(1), 83–91 (2011)
Chladek, G., Basa, K., Mertas, A., Pakieła, W., Żmudzki, J., Bobela, E., Król, W.: Effect of storage in distilled water for three months on the antimicrobial properties of poly(methyl methacrylate) denture base material doped with inorganic filler. Materials 9(5), 1–17 (2015)
Dwivedi, H., Jain, G., Jain, R.A.: Comparative evaluation of bite force as a parameter for the stability in conventional and three-dimensional mini plates. Indian J. Dent. Sci. 10(3), 133 (2018)
Hingsammer, L., Grillenberger, M., Schagerl, M., Malek, M., Hunger, S.: Biomechanical testing of zirconium dioxide osteosynthesis system for LeFort I advancment osteotomy fixation. J. Med. Behav. Biomed. Mater. 77, 34–39 (2018)
Król, M., Tańsk, T.I.: Surface quality research for selective laser melting of Ti-6Al-4V alloy. Arch. Metall. Mater. 61(3), 1291–1296 (2016)
Kumar, S.T., Saraf, S., Devi, S.P.: Evaluation of bite force after open reduction and internal fixation using microplates. J. Dent. Tehran 10(5), 466–477 (2013)
Mower, T.M., Long, M.J.: Mechanical behaviour of additive manufactured, powder-bed laser-fused materials. Mater. Sci. Eng. A 651A, 198–213 (2016)
Niedzielska, I., Puszczewicz, Z., Mertas, A., Niedzielski, D., Różanowski, B., Baron, S., Konopka, T., Skucha-Nowak, M., Tanasiewicz, M., Paluch, J., Markowski, J., Orzechowska-Wylęgała, B., Król, W., Morawiec, T.: The influence of ethanolic extract of Brazilian green propolis gel on hygiene and oral microbiota in patients after mandible fractures. BioMed Res. Int. vol. 2016, 1–11 (2016)
Reimann, Ł., Żmudzki, J., Dobrzański, L.A.: Strength analysis of a three-unit dental bridge framework with the Finite Element Method. Acta Bioeng. Biomech. 15(1), 51–59 (2015)
Rosenquist, B., Wall, G.: Mobility of the osteotomy site following Le Fort I osteotomy stabilized by titanium plate osteosynthesis. J. Oral Maxillofac. Surg. 53(11), 1276–1282 (1995)
Scolozzi, P.: Distraction osteogenesis in the management of severe maxillary hypoplasia in cleft lip and palate patients. J. Craniofac. Surg. 19(5), 1199–1214 (2008)
Stephens Li, K.K., Gliklich, W.L.: Reconstruction of the severely atrophic edentulous maxilla using Le Fort I osteotomy with simultaneous bone graft and implant placement. J. Oral Maxillofac. Surg. 54(5), 542–546 (1996)
Thompson, S.M., Yohuno, D., Bradley, W.N., Crocombe, A.D.: Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent. Knee Surg. Sports Traumatol. Arthrosc. 24(8), 2560–2566 (2016)
Walke, W., Marciniak, J., Paszenda, Z., Kaczmarek, M., Cieplak, J.: Biomechanical behaviour of double threaded screw in tibia fixation. Inf. Technol. Biomed. 47, 521–528 (2008)
Wang, H., Chen, M.S., Fan, Y.B., Tang, W., Tian, W.D.: Biomechanical evaluation of Le Fort I maxillary fracture plating techniques. J. Oral Maxillofac. Surg. 65(6), 1109–1116 (2007)
Yoon, H.J., Rebellato, J., Keller, E.E.: Stability of the le fort i osteotomy with anterior internal fixation alone: a case series. J. Oral Maxillofac. Surg. 63(5), 629–634 (2005)
Żmudzki, J., Chladek, G., Kasperski, J., Dobrzański, L.A.: One versus two implant-retained dentures: comparing biomechanics under oblique mastication forces. J. Biomech. Eng. 135(5), 054503-1–054503-4 (2013)
Żmudzki, J., Chladek, G., Kasperski, J.: Biomechanical factors related to occlusal load transfer in removable complete dentures. Biomech. Model. Mechanobiol. 14(4), 679–691 (2015)
Żmudzki, J., Chladek, G., Kasperski, J.: Single implant-retained dentures: loading of various attachment types under oblique occlusal forces. J. Mech. Med. Biol. 12(5), 1250087-1–1250087-11 (2012)
Żmudzki, J., Chladek, G., Kasperski, J.: The influence of lower complete denture destabilization under oblique mastication forces on the level of denture foundation soft tissue compression. Acta Bioeng. Biomech. 14(3), 67–73 (2012)
Żmudzki, J., Chladek, G., Krawczyk, C.: Relevance of tongue force on mandibular denture stabilization during mastication. J. Prosthodont. 28(8), 27–33 (2019)
Żmudzki, J., Chladek, G., Malara, P.: Use of finite element analysis for the assessment of biomechanical factors related to pain sensation beneath complete dentures during mastication. J. Prosthet. Dent. 100(6), 934–941 (2018)
Żmudzki, J., Chladek, W., Lipski, T.: Influence of tongue activity on lower complete denture retention under biting forces. Acta Bioeng. Biomech. 10(3), 13–20 (2008)
Żmudzki, J., Malara, P., Chladek, G.: Full contoured tooth-implant supported 3-pointic all-ceramic denture during occlusal load transfer in lateral region. Arch. Metall. Mater. 61(2), 843–846 (2016)
Żmudzki, J., Walke, W., Chladek, W.: Influence of model discretization density in FEM numerical analysis on the determined stress level in bone surrounding dental implants. Inf. Technol. Biomed. 47, 559–567 (2008)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Bobik, G., Żmudzki, J., Tański, T. (2021). Simulation Investigation of Occlusal Loads Transfer in Personalized Titanium Plates in the Case of Jaw Osteotomy. In: Gzik, M., Paszenda, Z., Pietka, E., Tkacz, E., Milewski, K. (eds) Innovations in Biomedical Engineering. AAB 2020. Advances in Intelligent Systems and Computing, vol 1223. Springer, Cham. https://doi.org/10.1007/978-3-030-52180-6_11
Download citation
DOI: https://doi.org/10.1007/978-3-030-52180-6_11
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-52179-0
Online ISBN: 978-3-030-52180-6
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)