Abstract
This technical note demonstrates the relevance of the isotropic 3D T2 turbo-spin-echo (TSE) sequence with short-term inversion recovery (STIR) and variable flip angle RF excitations (SPACE: Sampling Perfection with Application optimized Contrasts using different flip angle Evolutions) for high-resolution brachial plexus imaging. The sequence was used in 11 patients in the diagnosis of brachial plexus pathologies involving primary and secondary tumors, and in six volunteers. We show that 3D STIR imaging is not only a reliable alternative to 2D STIR imaging, but it also better evaluates the anatomy, nerve site compression and pathology of the plexus, especially to depict space-occupying tumors along its course. Finally, due to its appropriate contrast we describe how 3D-STIR can be used as a high-resolution mask to be fused with fraction of anisotropy (FA) maps calculated from diffusion tensor imaging (DTI) data of the plexus.
Similar content being viewed by others
References
Aagaard BD, Maravilla KR, Kliot M (1998) MR neurography MR imaging of peripheral nerves. Magn Reson Imaging Clin N Am 6(1):179–194
Kim S et al (2007) Role of magnetic resonance imaging in entrapment and compressive neuropathy-what, where, and how to see the peripheral nerves on the musculoskeletal magnetic resonance image: part 2. Upper extremity. Eur Radiol 17(2):509–522
Todd M, Shah GV, Mukherji SK (2004) MR imaging of brachial plexus. Top Magn Reson Imaging 15(2):113–125
van Es HW (2001) MRI of the brachial plexus. Eur Radiol 11(2):325–336
Gasparotti R et al (1997) Three-dimensional MR myelography of traumatic injuries of the brachial plexus. AJNR Am J Neuroradiol 18(9):1733–1742
Vargas MI et al (2007) Clinical applications of diffusion tensor tractography of the spinal cord. Neuroradiology. Oct 2; [Epub ahead of print] DOI 10.1007/s00234-007-0309-y
Zhou L, Yousem DM, Chaudhry V (2004) Role of magnetic resonance neurography in brachial plexus lesions. Muscle Nerve 30(3):305–309
Lichy MP et al (2005) Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences. Invest Radiol 40(12):754–760
Ducreux D et al (2005) Brain MR diffusion tensor imaging and fibre tracking to differentiate between two diffuse axonal injuries. Neuroradiology 47(8):604–608
Liberatore M et al (2006) Diffusion tensor imaging and tractography of central pontine myelinolysis. J Neuroradiol 33(3):189–193
Roze E et al (2007) Propriospinal myoclonus: Utility of magnetic resonance diffusion tensor imaging and fiber tracking. Mov Disord 22(10):1506–1509
Schwartz ED et al (2005) Spinal cord diffusion tensor imaging and fiber tracking can identify white matter tract disruption and glial scar orientation following lateral funiculotomy. J Neurotrauma 22(12):1388–1398
Acknowledgment
The authors thank Stefan Huwer and Heiko Maïer from the Siemens Advanced Neuro MR Development Group in Erlangen for helpful discussions and collaboration on the Neuro3D software.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Viallon, M., Vargas, M.I., Jlassi, H. et al. High-resolution and functional magnetic resonance imaging of the brachial plexus using an isotropic 3D T2 STIR (Short Term Inversion Recovery) SPACE sequence and diffusion tensor imaging. Eur Radiol 18, 1018–1023 (2008). https://doi.org/10.1007/s00330-007-0834-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-007-0834-4