Abstract
The ultraviolet (UV) Fluorescent Aerodynamic Particle Sizer (FLAPS), a flow cytometer-like apparatus was developed by the Canadian Department of National Defence for real-time detection of autofluorescence of biological aerosol particles such as bacterial spores. The direct relation between autofluorescence intensity and viability has recently been reported and viable spore are more autofluorescent in UV (Laflamme, Frontiers in Bioscience). The goal of this manuscript is to describe a flow cytometry sorting protocol based on UV-induced autofluorescence. An EPICS® ELITE ESP flow cytometer equipped with a UV laser and cell sorter was used to mimic the optical properties of FLAPS and to study the two extremes of a spore population according to its autofluorescence (lower level of autofluorescence (LLA) and higher level of autofluorescence (HLA) spores). Bacillus subtilis var niger was used as a surrogate for Bacillus anthracis spores and sorted using autofluorescence intensity as the main criterion. The protocol developed in our laboratory to sort Bacillus spores according to their autofluorescence properties is described. Purity of each sorted population was greater than 95%. Using autofluorescence as the main criterion, we demonstrate that it is possible to separate two distinct spore populations.
References
Hairston PP, Ho J, Quant FR (1997) Design of an instrument for real-time detection of bioaerosols using simultaneous measurement of particle aerodynamic size and intrinsic fluorescence. J Aerosol Sci 28:471–482
Ho J, Spence M, Hairston P (2000) Measurement of biological aerosol with a fluorescent aerodynamic particle sizer (FLAPS): correlation of optical data with biological data. In: Stopa PJ, Bartoszcze MA (Eds). Rapid methods for analysis of biological materials in the environment. Kluwer Academic Publishers, Netherlands p 177–201
Horvath JJ, Glazier SA, Spangler CJ (1993) In situ fluorescence cell mass measurements of Saccharomyces cerevisiae using cellular tryptophan. Biotechnol Prog 9:666–670
Benson RC, Meyer RA, Zaruba ME, McKhann GM (1979) Cellular autofluorescence—Is it due to flavins? J Histochem Cytochem 27:44–48
Aubin JE (1979) Autofluorescence of viable cultured mammalian cells. J Histochem Cytochem 27:36-43
Pouneva I (1997) Evaluation of algal culture viability and physiological state by fluorescencent microscopic methods. Bulg J Plant Physiol 23:67–76
Shimazaki J, Laing RA, Tsubota K, Kenyon KR (1996) Non-invasive assessment of the donor corneal endothelial using ocular redox fluorometry. Br J Opthalmol 80:69–73
Caiola MG, Ocampo-Friedmann R, Friedmann EI (1993) Cytology of long-term desiccation in the desert cyanobacterium Chroococcidiopsis (Chroococcales). Phycologia 32:315–322
Tokunaga Y, Ozaki N, Wakashiro S, Ikai I, Morimoto T, Shimahara Y, Kamiyama Y, Yamaoka Y, Ozawa K, Nakase Y (1987) Fluorometric study for the noninvasive determination of cellular viability in perfused rat liver. Transplantation 44:701–706
Eng J, Lynch RM, Balaban RS (1989) Nicotiamide adenine dinucleotide fluorescence spectroscopy and imaging in isolated cardiac myocytes. Biophy J 55:621–630
Laflamme C, Verreault D, Lavigne S, Trudel L, Ho J, Duchaine C (2005) Autofluorescence as a viability marker for detection of bacterial spores. Front Biosci 10:1647–1653
Herzenberg LA, Parks D, Sahaf B, Perez O, Roederer M, Herzenberg LA (2002) The history and future of the fluorescence activated cell sorter and flow cytometry: a view from Stanford. Clin Chem 48:1819–1827
Melamed MR (2001) A brief history of flow cytometry and sorting. In: Methods in cell biology. vol 63, p 3–17
Ibrahim SF, Van Den Engh G (2004) High-speed chromosome sorting. Chromosome Res 12:5–14
Johnson LA, Flook JP, Look MV (1987) Flow cytometry of X and Y chromosome-bearing sperm for DNA using an improved preparation method and staining with Hoechst 33342. Gamete Res 17:203–212
Garner DL (2001) Sex-Sorting mammalian sperm: concept to application in animals. J Androl 22:519–26
Goodell MA, Brose K, Paradis G, Stewart Conner A, Mulligan RC (1996) Isolation and functional properties of murine hematopoietic stem cells that are replicating in vivo. J Exp Med 183:1797–1806
Sneath PHA (1986) Bergey's manual of systematic bacteriology. vol 2. Baltimore: Williams & Wilkins
Acknowledgements
These studies were undertaken under a Department of National Defence (DND) contract W7702-00R802/001/EDM: Dr. J. Ho was the scientific authority acting for DND. Initial ideas for these studies originated from previous work performed at DND. The authors are thankful to Dr. André Darveau and Maurice Dufour for their insightful review of the manuscript. Christian Laflamme received a Natural Sciences and Engineering Research Council of Canada (NSERC)/Institut de recherche Robert-Sauvé en santé et sécurité du travail (IRSST) studentship. Dr. C. Duchaine acknowledges an Institut de Recherche Robert-Sauvé en Santé et Sécurité du Travail/Canadian Institutes of Health Research Scholarship.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Laflamme, C., Verreault, D., Ho, J. et al. Flow Cytometry Sorting Protocol of Bacillus Spore Using Ultraviolet Laser and Autofluorescence as Main Sorting Criterion. J Fluoresc 16, 733–737 (2006). https://doi.org/10.1007/s10895-006-0129-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10895-006-0129-1