Skip to main content
Log in

Flow injection on-line preconcentration coupled to hydride generation atomic fluorescence spectrometry for ultra-trace amounts of cadmium determination in seawater

  • Original Paper
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract.

A simple flow injection on line separation and preconcentration system coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) was developed for ultra-trace cadmium determination in seawater. With the sample pH kept at 3.0, the preconcentration of cadmium on the inner walls of the knotted reactor was carried out based on the retention of cadmium complex with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one. A 0.2 mol L−1 HCl was introduced to elute the retained analyte complex and merge with KBH4 solution for HG-AFS detection. Under the optimal experimental conditions, an enhancement factor of 12 was obtained with a sample consumption of 12.0 mL. The limit of detection was 3.2 ng L−1 with a sample frequency of 24 h−1. The developed method was validated by the analysis of cadmium in certified reference materials, and was applied to the determination of cadmium in four seawater samples with R.S.D. of around 10%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • M F Enríquez-Domínquez M C Yebra-Biurrun M P Bermejo-Barrera (1998) ArticleTitleDetermination of cadmium in mussels by flame atomic absorption spectrometry with preconcentration on a chelating resin in a flow injection system Analyst 123 105 Occurrence Handle10.1039/a705748b

    Article  Google Scholar 

  • J A Jurado-González M D Galindo-Riaño M García-Vargas (2003) ArticleTitleExperimental designs in the development of a new method for the sensitive determination of cadmium in seawater by adsorptive cathodic stripping voltammetry Anal Chim Acta 487 229 Occurrence Handle10.1016/S0003-2670(03)00536-1

    Article  Google Scholar 

  • M C Yebra-Biurrun A Moreno-Cid L Puig (2004) ArticleTitleMinicolumn field preconcentration and flow-injection flame atomic absorption spectrometry determination of cadmium in seawater Anal Chim Acta 524 73 Occurrence Handle10.1016/j.aca.2004.05.052 Occurrence Handle1:CAS:528:DC%2BD2cXnvVOgs7o%3D

    Article  CAS  Google Scholar 

  • J F Wu E A Boyle (1997) ArticleTitleLow blank preconcentration technique for the determination of lead, copper, and cadmium in small-volume seawater samples by isotope dilution ICP-MS Anal Chem 69 2464 Occurrence Handle10.1021/ac961204u Occurrence Handle1:CAS:528:DyaK2sXjsVOitr8%3D

    Article  CAS  Google Scholar 

  • V A Lemos P X Baliza (2005) ArticleTitleAmberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copper Talanta 67 564 Occurrence Handle10.1016/j.talanta.2005.03.012 Occurrence Handle1:CAS:528:DC%2BD2MXpsFyltbk%3D

    Article  CAS  Google Scholar 

  • M C Yebra M F Enriquez R M Cespon (2000) ArticleTitlePreconcentration and flame atomic absorption spectrometry determination of cadmium in mussels by an on-line continuous precipitation-dissolution flow system Talanta 52 631 Occurrence Handle10.1016/S0039-9140(00)00367-2 Occurrence Handle1:CAS:528:DC%2BD3cXlvVGjtr4%3D

    Article  CAS  Google Scholar 

  • Y Wang M L Chen J H Wang (2006) ArticleTitleSequential/bead injection lab-on-valve incorporating a renewable microcolumn for co-precipitate preconcentration of cadmium coupled to hydride generation atomic fluorescence spectrometry J Anal At Spectrom 21 535 Occurrence Handle10.1039/b601039c Occurrence Handle1:CAS:528:DC%2BD28XktVemtrs%3D

    Article  CAS  Google Scholar 

  • A N Anthemidis G A Zachariadis J A Stratis (2003) ArticleTitleDevelopment of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples J Anal At Spectrom 18 1400 Occurrence Handle10.1039/b308325j Occurrence Handle1:CAS:528:DC%2BD3sXos1Cmsrg%3D

    Article  CAS  Google Scholar 

  • G Z Fang J Tan X P Yan (2005) ArticleTitleAn ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique combined with a sol-gel process for selective solid-phase extraction of cadmium(II) Anal Chem 77 1734 Occurrence Handle10.1021/ac048570v Occurrence Handle1:CAS:528:DC%2BD2MXovFSluw%3D%3D

    Article  CAS  Google Scholar 

  • C R T Tarley A F Barbosa M G Segatelli E C Figueiredo P O Luccas (2006) ArticleTitleHighly improved sensitivity of TS-FF-AAS for Cd(II) determination at ng L−1 levels using a simple flow injection minicolumn preconcentration system with multiwall carbon nanotubes J Anal At Spectrom 21 1305 Occurrence Handle10.1039/b606997e

    Article  Google Scholar 

  • S Cerutti M F Silva J A Gasquez R A Olsina L D Martinez (2003) ArticleTitleOn-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer Spectrochim Acta Part B 58 43 Occurrence Handle10.1016/S0584-8547(02)00215-X

    Article  Google Scholar 

  • J Munoz J R Baena M Gallego M Valcarcel (2002) ArticleTitleDevelopment of a method for the determination of inorganic cadmium and cadmium metallothioneins in fish liver by continuous preconcentration on fullerene and flame atomic absorption spectrometry J Anal At Spectrom 17 716 Occurrence Handle10.1039/b202535n Occurrence Handle1:CAS:528:DC%2BD38XltVKkuro%3D

    Article  CAS  Google Scholar 

  • M Miró S Jończyk J H Wang E H Hansen (2003) ArticleTitleExploiting the bead-injection approach in the integrated sequential injection lab-on-valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior to ETAAS detection J Anal At Spectrom 18 89 Occurrence Handle10.1039/b212024k

    Article  Google Scholar 

  • X P Yan Y Jiang (2001) ArticleTitleFlow injection on-line preconcentration and separation coupled with atomic(mass) spectrometry for trace element (speciation) analysis based on sorption of organo-metallic complexes in a knotted reactor Trends Anal Chem 20 552 Occurrence Handle10.1016/S0165-9936(01)00110-8 Occurrence Handle1:CAS:528:DC%2BD3MXnslCktLY%3D

    Article  CAS  Google Scholar 

  • Z L Fang S K Xu L P Dong W Q Li (1994) ArticleTitleDetermination of cadmium in biological materials by flame atomic absorption spectrometry with flow-injection on-line sorption preconcentration Talanta 41 2165 Occurrence Handle10.1016/0039-9140(94)00204-5 Occurrence Handle1:CAS:528:DyaK2MXjsFeku74%3D

    Article  CAS  Google Scholar 

  • Q Y Ye Y Li Y Jiang X P Yan (2003) ArticleTitleDetermination of trace cadmium in rice by flow injection on-line filterless precipitation-dissolution preconcentration coupled with flame atomic absorption spectrometry J Agric Food Chem 51 2111 Occurrence Handle10.1021/jf025945+ Occurrence Handle1:CAS:528:DC%2BD3sXitVOltrs%3D

    Article  CAS  Google Scholar 

  • S Cerutti S L C Ferreira J A Gásquez R A Olsina L D Martinez (2004) ArticleTitleOptimization of the preconcentration system of cadmium with 1(2-thiazolylazo)-p-cresol using a knotted reactor and flame atomic absorption spectrometric detection J Hazard Mater 112 279 Occurrence Handle10.1016/j.jhazmat.2004.05.017 Occurrence Handle1:CAS:528:DC%2BD2cXmtlOrsL0%3D

    Article  CAS  Google Scholar 

  • A S Souza W N L dos Santos S L C Ferreira (2005) ArticleTitleApplication of Box-Behnken design in the optimisation of an on-line pre-concentration system using knotted reactor for cadmium determination by flame atomic absorption spectrometry Spectrochim Acta Part B 60 737 Occurrence Handle10.1016/j.sab.2005.02.007

    Article  Google Scholar 

  • E Ivanova W Van Mol F Adams (1998) ArticleTitleElectrothermal atomic absorption spectrometric determination of cadmium and lead in blood using flow injection on-line sorption preconcentration in a knotted reactor Spectrochim Acta Part B 53 1041 Occurrence Handle10.1016/S0584-8547(98)00097-4

    Article  Google Scholar 

  • I Benkhedda E Ivanova F Adams (1999) ArticleTitleFlow injection on-line sorption preconcentration of trace amounts of copper and manganese in a knotted reactor precoated with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one coupled with electrothermal atomic absorption spectrometry J Anal At Spectrom 14 957 Occurrence Handle10.1039/a900630c Occurrence Handle1:CAS:528:DyaK1MXkt1ersLs%3D

    Article  CAS  Google Scholar 

  • R F Lara R G Wuilloud J A Salonia R A Olsina L D Martinez (2001) ArticleTitleDetermination of low cadmium concentrations in wine by on-line preconcentration in a knotted reactor coupled to an inductively coupled plasma optical emission spectrometer with ultrasonic nebulization Fresenius’ J Anal Chem 371 989 Occurrence Handle10.1007/s00216-001-1096-7 Occurrence Handle1:CAS:528:DC%2BD3MXos1Citb4%3D

    Article  CAS  Google Scholar 

  • K Benkhedda H G Infante E Ivanova F C Adams (2000) ArticleTitleTrace metal analysis of natural waters and biological samples by axial inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS) with flow injection on-line adsorption preconcentration using a knotted reactor J Anal At Spectrom 15 1349 Occurrence Handle10.1039/b003997g Occurrence Handle1:CAS:528:DC%2BD3cXntVCrtLs%3D

    Article  CAS  Google Scholar 

  • W Chuachuad J F Tyson (2005) ArticleTitleDetermination of cadmium by flow injection atomic absorption spectrometry with cold vapor generation by a tetrahydroborate-form anion-exchanger J Anal At Spectrom 20 273 Occurrence Handle10.1039/b416355a Occurrence Handle1:CAS:528:DC%2BD2MXisVGjs7g%3D

    Article  CAS  Google Scholar 

  • G Li L Wu J J Xin X G Hou (2004) ArticleTitleChemical vapor generation by reaction of cadmium with potassium tetrahydroborate and sodium iodate in acidic aqueous solution for atomic fluorescence spectrometric application J Anal At Spectrom 19 1010 Occurrence Handle10.1039/b402581d Occurrence Handle1:CAS:528:DC%2BD2cXmt1Kqurw%3D

    Article  CAS  Google Scholar 

  • H W Sun R Suo (2004) ArticleTitleEnhancement reagents for simultaneous vapor generation of zinc and cadmium with intermittent flow system coupled to atomic fluorescence spectrometry Anal Chim Acta 509 71 Occurrence Handle10.1016/j.aca.2003.12.024 Occurrence Handle1:CAS:528:DC%2BD2cXitFaqsrc%3D

    Article  CAS  Google Scholar 

  • T C Duan X J Song D Jin H F Li J W Xu H T Chen (2005) ArticleTitlePreliminary results on the determination of ultratrace amounts of cadmium in tea samples using a flow injection on-line solid phase extraction separation and preconcentration technique to couple with a sequential injection hydride generation atomic fluorescence spectrometry Talanta 67 968 Occurrence Handle10.1016/j.talanta.2005.04.017 Occurrence Handle1:CAS:528:DC%2BD2MXhtVClu7zJ

    Article  CAS  Google Scholar 

  • W E Gan W W Shi Q D Su (2004) ArticleTitleSimultaneous determination of trace mercury and cadmium in tobacco samples by cold vapor generation-atomic fluorescence spectrometry J Anal At Spectrom 19 911 Occurrence Handle10.1039/b402545h Occurrence Handle1:CAS:528:DC%2BD2cXlsFansbs%3D

    Article  CAS  Google Scholar 

  • H W Sun R Suo Y K Lu (2003) ArticleTitleSimultaneous determination of trace cadmium and mercury in Chinese herbal medicine by non-dispersive atomic fluorescence spectrometry using intermittent flow vapor generator Anal Sci 19 1045 Occurrence Handle10.2116/analsci.19.1045 Occurrence Handle1:CAS:528:DC%2BD3sXlslGlsb8%3D

    Article  CAS  Google Scholar 

  • Y K Lu H W Sun C G Yuan X P Yan (2002) ArticleTitleSimultaneous determination of trace cadmium and arsenic in biological samples by hydride generation-double channel atomic fluorescence spectrometry Anal Chem 74 1525 Occurrence Handle10.1021/ac0156971

    Article  Google Scholar 

  • H Wu Y Jin W Y Han Q Miao S P Bi (2006) ArticleTitleNon-chromatographic speciation analysis of mercury by flow injection on-line preconcentration in combination with chemical vapor generation atomic fluorescence spectrometry Spectrochim Acta Part B 61 831 Occurrence Handle10.1016/j.sab.2006.04.008

    Article  Google Scholar 

  • H Wu Y Jin Y Q Shi S P Bi (2007) ArticleTitleOn-line organoselenium interference removal for inorganic selenium species by flow injection coprecipitation preconcentration coupled with hydride generation atomic fluorescence spectrometry Talanta 71 1762 Occurrence Handle10.1016/j.talanta.2006.08.011 Occurrence Handle1:CAS:528:DC%2BD2sXit1ylurg%3D

    Article  CAS  Google Scholar 

  • K Benkhedda H G Infante E Ivanova F Adams (2000) ArticleTitleUltratrace determination of cobalt in natural waters by electrothermal atomic absorption spectrometry using flow-injection on-line sorption preconcentration in a knotted reactor precoated with 1-phenyl-3-methyl-benzoylpyrazol-5-one J Anal At Spectrom 15 429 Occurrence Handle10.1039/a908907a Occurrence Handle1:CAS:528:DC%2BD3cXit1GisLg%3D

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hong Wu.

Additional information

Correspondence: Hong Wu, Department of Chemistry, Xuzhou Normal University, Xuzhou 221116, P.R. China

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wu, H., Fang, C., Du, B. et al. Flow injection on-line preconcentration coupled to hydride generation atomic fluorescence spectrometry for ultra-trace amounts of cadmium determination in seawater. Microchim Acta 160, 173–178 (2008). https://doi.org/10.1007/s00604-007-0808-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00604-007-0808-x

Navigation