Poor correlation between body surface area and glomerular filtration rate

  • ORIGINAL ARTICLE
  • Published:
Cancer Chemotherapy and Pharmacology Aims and scope Submit manuscript

Abstract

Purpose: The aim of this study was to determine the correlation between body surface area (BSA) and glomerular filtration rate (GFR) measured by Tc-99m DTPA clearance in adult patients with cancer. Methods: GFR was determined by Tc-99m DTPA clearance in adult patients with cancer. Height and actual body weight were measured. Ideal body weight was calculated. BSA was calculated using the Du Bois and Du Bois linear method using both actual and ideal body weight. Results: Included in the study were 122 patients. The mean GFR measured by Tc-99m DTPA clearance was 87 ml/min (range 30–174 ml/min). The mean BSA (actual weight) was 1.76 m2 (median 1.73 m2, range 1.31–2.58 m2). The mean BSA (ideal body weight) was 1.63 m2 (median 1.63 m2, range 1.20–2.00 m2). The overall correlation between BSA (actual weight) and GFR in this adult population was r=0.24, and the 95% confidence interval was 0.06–0.4. The correlation between BSA (ideal body weight) and GFR was r=0.22. The correlation between BSA and GFR excluding patients with a BSA <1.5 m2 or >2.0 m2 was 0.12. When patients with GFR <50 ml/min or >100 ml/min were excluded, the correlation with BSA was 0.07. The correlations between GFR and height, actual weight and ideal weight were 0.22, 0.21 and 0.22, respectively. Conclusions: This study demonstrated a poor correlation between GFR determined by Tc-99m DTPA clearance and BSA calculated using the Du Bois and Du Bois linear method. The 95% confidence interval for the correlation between BSA and GFR was 0.06–0.4 indicating that a strong applicable clinical correlation is very unlikely.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 3 February 2000 / Accepted: 17 July 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dooley, M., Poole, S. Poor correlation between body surface area and glomerular filtration rate. Cancer Chemother Pharmacol 46, 523–526 (2000). https://doi.org/10.1007/PL00006751

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/PL00006751

Navigation